The following instructions are provided for qualified installers
so that they may accomplish installation, adjustment and
technical maintenance operations correctly and in
compliance with national current regulations and standards.

Important: the appliance should be disconnected from
the mains electricity supply before any adjustment,
maintenance, etc. is carried out.

 Maximum caution should

be exercised should it be necessary to keep the appliance
connected to the electricity supply.

The cookers have the following technical specifications:

Cat. II2H3+

The maximum dimensions of the appliance are given in the

figure on page 2. For trouble-free operation of appliances

installed in housing units, the minimum distances shown in

fig.8 should be observed. Adjacent surfaces and the wall at

the rear should also be able to withstand a temperature of

65 °C

Prior to installing the cooker, 99 ÷ 155 mm high supporting
feet (provided) should be fitted into the holes to be found in
the bottom of the cooker (fig.9). These feet are screw-
adjustable and whenever necessary should be used to make
sure the cooker stands level.

Positioning

This appliance  may only be installed and operated in
permanently ventilated rooms in compliance with provisions
laid down by current regulations and standards. The following
requirements must be observed:

• The appliance must discharge combustion products into a

special hood, which must be connected to a chimney, flue
pipe or directly to the outside (fig.10).

• If it is impossible to fit a hood, the use of an electric fan is

permitted, either installed on a window or on an external
wall, which must be switched on at the same time as the
appliance.

INSTRUCTIONS FOR THE INSTALLER

In a chimney stack or branched flue

Directly to the outside

(exclusively for cooking appliances)

Kitchen ventilation

The air flow into the room where the appliance is installed
must be equal to the quantity of air that is required for regular
combustion of the gas and for ventilating the same room.
Air must be taken in naturally through permanent apertures
made in the outside walls of the room or through single or
branching collective ventilation ducts in compliance with the
standards in force. The air must be taken directly from the
outside, from an area far from sources of pollution.  The
ventilation aperture must have the following characteristics
(fig.11A):
• total free cross section of passage of at least 6 cm² for

every kW of rated heating capacity of the appliance, with
a minimum of 100 cm² (the heating capacity is indicated
on the rating plate);

• it must be made in such a way that the aperture cannot be

obstructed both on the inside and outside of the wall;

• it must be protected, e.g. with grills, wire mesh, etc. in

such a way that the above-mentioned free section is not
reduced;

• it must be situated as near to floor level as possible.

Detail A

Adjacent

Room  to be

room

 ventilated

A

Examples of ventilation holes

Enlarging the ventilation slot

for comburant air

 between window and floor

fig. 11A

fig.11B

The air inflow may also be obtained from an adjoining room,
provided the latter is not a bedroom or a room where there
is a risk of fire, such as warehouses, garages, fuel stores,
etc. and is ventilated in compliance with the standards in
force. Air from the adjoining room to the one to be ventilated
may be made to pass freely through permanent apertures
with a cross section at least equal to that indicated above.
These apertures may also be obtained by increasing the
gap between the door and the floor (fig.11B). If an electric
fan is used for extracting the combustion products, the
ventilation aperture must be increased in relation to its
maximum performance. The electric fan should have a

fig.9

fig.10

fig.8

min. 50mm

min.

700mm

Class 1           Class 2 sub-class 1

Summary of Contents for CP 057 GT

Page 1: ...P 059 MD 3 X F Cucina mista Istruzioni per l uso e l installazione Mixed cooker Instructions for use and installation Cuisinière mixte Instructions pour l emploi et l installation Cocina mixta Instrucciones para el uso y la instalación Fogão Misto Instruções para o uso e a instalação ...

Page 2: ...st When ordering this please give the code BAB followed by the appliance model The model is stamped on the rating plate affixed to the rear of the appliance and at the back of this booklet 9 Check that the capacity of the electrical system and the power outlets are suitable for the maximum power of WARNINGS THESE INSTRUCTIONS ARE ONLY VALID FOR THE COUNTRIES OF DESTINATION WHOSE SYMBOLS ARE SHOWN ...

Page 3: ...afts etc interrupting the supply of gas to the burner G Electric oven selector knob cooking mode selection H Electric oven thermostat knob temperature selec tion M Control knobs for gas burners R Support grid for cookware P Timer S Electric heating element indicator light T Minute minder U End of cooking programmer V Gas oven thermostat knob gas oven mode selector with temperature adjustment and e...

Page 4: ...e for the burner being used so that the flame does not extend beyond the pan base see the following table When a liquid starts boiling we recommend you turn the flame down just enough to keep the liquid simmering fig 2 The dual independent flame burner This gas burner consists of two concentric burner rings which can be actuated together or independently When the two rings are used together at the...

Page 5: ...This device automatically cuts off the gas from the burner in a few seconds should the flame accidentally go out Lighting the oven burner open the oven door press and turn the thermostat knob V with the symbol and set it to maximum keep it pushed Should there not be any electric energy hold a lighted match near the central hole on the oven bottom as in fig 3 fig 3 keep the knob pressed in for arou...

Page 6: ...e has been reached inside the oven When the light alternately comes on and goes out it means that the thermostat is working properly to maintain the oven temperature constant Timer U mod CP 058 MT 2 Manual operation Turn the timer knob with symbol anti clockwise and set the marker to symbol manual Turn the oven on at the selector knob and set the desired temperature on the thermostat knob To turn ...

Page 7: ...show the current time within 4 seconds When auto is lighted it indicates that the length and end cooking time have been preset to operate in automatic mode At this point the oven will turn on automatically at 12 30 in order to finish the cooking session within 30 minutes When the oven is on the symbol cooking pot will appear on the display for the entire length of the cooking process The button ca...

Page 8: ...n the oven is cold The steel parts and especially the areas with the screen printed symbols should not be cleaned with solvents or abrasive detergents It is advisable to use only a damp cloth with lukewarm water and washing up liquid Stainless steel may remain stained if in long term contact with very calcareous water or aggressive detergents containing phosphorus It is therefore always necessary ...

Page 9: ...m 5 2 5 1 h s i d f o e p y T m o t t o b m o r f o n l i a r e d i u G g k y t i t n a u Q C e r u t a r e p m e T s e t u n i m e m i T s e k a C d l u o m n i x i m n e t a e b h t i W d l u o m t u o h t i w x i m n e t a e b h t i W e s a b n a l f y r t s a p t r o h S g n i l l i f t e w h t i w y r t s a p t r o h S g n i l l i f y r d h t i w y r t s a p t r o h S x i m d e n e v a e l l ...

Page 10: ...appliances Kitchen ventilation The air flow into the room where the appliance is installed must be equal to the quantity of air that is required for regular combustion of the gas and for ventilating the same room Air must be taken in naturally through permanent apertures made in the outside walls of the room or through single or branching collective ventilation ducts in compliance with the standar...

Page 11: ...ck its condition it should be replaced before the date printed on the ac tual pipe A fig 13 fig 12 Important A pressure regulator in compliance with the applicable norm in force must be inserted when connecting to a liquid gas supply in a cylinder Upon completion of installation check for leaks from the gas circuit using a soapy solution never use a flame Make sure that the natural gas pipe is ade...

Page 12: ...e low flame position Remove the knob and turn the adjusting screw situated to the right of the tap fig 14 until you obtain a regular small flame using a screwdriver loosening the screw increases the height of the flame tightening decreases it N B In the case of liquid gas the regulation screw must be screwed in all the way Having obtained the low flame setting required and with the burner lit abru...

Page 13: ...rvice Centre informing them of The type of problem The abbreviation used to identify the model Mod as indicated on the warranty Never call on technicians not authorised by the manufacturer and always refuse to accept spare parts that are not original 1 e l b a T s a g d i u q i L s a g l a r u t a N R E N R U B r e t e m a i D m m r e w o p l a m r e h T s H W k s s a p y B 0 0 1 1 m m r o t c e j...

Page 14: ...viale Aristide Merloni 47 60044 Fabriano tel 0732 6611 telex 560196 fax 0732 662954 www Merloni com Mod ARISTON 09 03 code 195037300 01 Xerox Business Services Docutech ...