11
Be sure power is not connected to the door opener
BEFORE installing the safety reversing sensor.
To prevent SERIOUS INJURY or DEATH from a closing
door:
• Correctly connect and align the safety reversing
sensor. This required safety device MUST NOT be
disabled.
• Install the safety reversing sensor so beam is NO
HIGHER than 100mm (4”) above the floor.
Mounting Bracket
With Square Holes
#10-32x3/8"
Screws
"C" Wrap
#10-32
Lock Nuts
ALL Installations
figure 1
INSTALLING THE BRACKETS
Be sure power to the opener is disconnected.
Figures 1, 2 and 3 show recommended assembly of
bracket(s) and "C" wrap based on the
wall
installation of
the sensors on each side of the door shown above, or on
the
door tracks
themselves. Figures 4, 5 & 6 show
variations which may fit your installation requirements
better.
Make sure the wraps and brackets are aligned
so the sensors will face each other across the door.
• Connect each assembly to a slotted bracket, using the
hardware shown.
Note alignment of brackets for left
and right sides of the door.
Finger tighten the lock
nuts.
•
Use bracket mounting holes as a template to locate and
drill (2) (4.8mm) diameter pilot holes on both sides of the
door, (100mm). Max height is (100mm).
• Attach bracket assemblies with 1/4"x1-1/2" lag screws as
shown.
• Adjust right and left side bracket assemblies to the same
distance out from mounting surface. Make sure all door
hardware obstructions are cleared. Tighten the nuts
securely.
•
Centre each sensor unit in a "C" wrap with lenses
pointing toward each other across the door.
• Secure sensors with the hardware shown in Figure 6.
Finger tighten the wing nut on the
receiving eye
to allow
for final adjustment. Securely tighten the
sending eye
wing
nut.
•
Run wires from both sensors to the opener as shown on
Page 12. Use insulated staples to secure the wire to the
wall and ceiling.
• Connect both sets of wires to the opener terminals as
shown page 12.
•
Plug in the opener. If your opener has the Multi-Function
Door Control, make sure the Lock Feature is
off
.
Red
indicator lights in both the sending and receiving eyes will
glow
if wiring connections and alignment are correct.
If the indicator lights are
flashing
(and the invisible light
beam path is not obstructed), alignment is required.
• Loosen the receiving eye wing nut to allow slight rotation
of unit. Adjust sensor vertically and/or horizontally until the
red indicator light
glows
.
• When indicator lights are glowing in both units, tighten the
wing nut in the receiving eye unit.
Mounting Bracket
with Slot
1/4"-20
Lock Nuts
1/4x1-1/2"
Lag Screws
1/4-20x1/2" Carriage Bolts
(with square shoulder)
Inside
Garage
Wall
"C" Wrap
Mounting Bracket
with Square Holes
"C" Wrap
Inside
Garage
Wall
Mounting
Bracket with
Square Holes
Garage
Floor
Mounting
Bracket
with Slot
Alternate Wall
Mount
Sensor
Inside
Garage
Wall
Alternate Floor
Mount
Mounting Bracket
with Slot
Mounting Bracket
with Square Holes
"C"
Wrap
Sensor
Garage
Floor
Indicator Light
Indicator Light
Attach with
concrete anchors
(not provided)
Inside
Garage
Wall
"C" Shaped
Wrap
Mounting Bracket
with Square Holes
1/4-20x1/2"
Carriage Bolts
1/4"-20
Lock Nuts
Drill 3/8"
(9,5mm) Holes
Garage
Door Track
Garage DOOR Track Installation
Garage WALL Installation
1/4-20x1-1/2"
Hex Bolt
"C" Wrap
Wire
Sensor
Wing Nut
Indicator
Light
figure 2
figure 3
figure 4
figure 5
INSTALLATION STEP 7
Install The Protector System
TM
When installed the safety reversing sensor
must
be
connected and aligned correctly before the door
opener will move in the down direction. This safety
device is provided for your safety and should not be
disabled.
NOTE: The speed will also be increased by 1/3 in the
down direction.
figure 6