Page 8
For technical questions, please call 1-888-866-5797.
Item 58547
SAFET
Y
OP
ERA
TION
M
AINTENAN
C
E
SETU
P
Operating Instructions
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
Filter/Regulator Area Set Up
Designate a work area that is clean and well-lit.
The work area must not allow access by
children or pets to prevent injury.
General Operation
Note:
At the beginning of the day’s first use of the
Filter/Regulator, check for air leaks by applying soapy
water to connections while the Filter/Regulator
is pumping and after pressure cut-out.
Look for air bubbles. If air bubbles are present at
connections, tighten connections. Do not use the
Filter/Regulator unless all connections are air tight,
the extra air leaking out will cause the regulator to
operate too often, increasing wear on the regulator.
WARNING!
TO PREVENT SERIOUS
INJURY AND DEATH FROM
EXPLOSION:
Do not exceed 200 PSI
1. Adjust the Regulator Handle so that the air output
is enough to properly power the tool, but the output
will not exceed the tool’s maximum air pressure
at any time. Turn the knob clockwise to increase
the pressure and counter-clockwise to decrease
pressure. Adjust the pressure gradually, while
checking the air output gauge to set the pressure.
2. Connector air hose to tool’s Air Outlet.
3. Make sure the air tool’s throttle or switch is in the
off position. Connect the air tool to the air hose.
4. Open the in-line Shutoff Valve.
5. Use the air tool as needed.
6. After the job is complete, turn the
compressor’s Power Switch OFF.
7. Disconnect the Filter/Regulator.
8. Close the in-line Shutoff Valve.
9. Bleed air from the tool then disconnect the tool.
10. Drain the Filter/Regulator of water daily. With the
unit under pressure, open the Drain Plug to expel
any accumulated moisture from the Air Filter.
11. Clean, then store the Filter/Regulator indoors.
Maintenance and Servicing
Procedures not specifically explained in this manual must
be performed only by a qualified technician.
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Turn the Power Switch “OFF” and unplug the Filter/Regulator from its electrical outlet
before performing any inspection, maintenance, or cleaning procedures.
TO PREVENT SERIOUS INJURY FROM FILTER/REGULATOR FAILURE:
Do not use damaged equipment. If abnormal noise or vibration occurs,
have the problem corrected before further use.