Filter/Regulator Area Set Up

Designate a work area that is clean and well-lit.  

The work area must not allow access by 

children or pets to prevent injury.

General Operation

Note:

  At the beginning of the day’s first use of the 

Filter/Regulator, check for air leaks by applying soapy 

water to connections while the Filter/Regulator 

is pumping and after pressure cut-out.  

Look for air bubbles.  If air bubbles are present at 

connections, tighten connections.  Do not use the 

Filter/Regulator unless all connections are air tight, 

the extra air leaking out will cause the regulator to 

operate too often, increasing wear on the regulator.

WARNING!

 

TO PREVENT SERIOUS 

INJURY AND DEATH FROM 

EXPLOSION:

  

Do not exceed 200 PSI

1.  Adjust the Regulator Handle so that the air output 

is enough to properly power the tool, but the output 

will not exceed the tool’s maximum air pressure 

at any time.  Turn the knob clockwise to increase 

the pressure and counter-clockwise to decrease 

pressure.  Adjust the pressure gradually, while 

checking the air output gauge to set the pressure.

2.  Connector air hose to tool’s Air Outlet.

3.  Make sure the air tool’s throttle or switch is in the 

off position.  Connect the air tool to the air hose.

4.  Open the in-line Shutoff Valve.

5.  Use the air tool as needed.

6.  After the job is complete, turn the 

compressor’s Power Switch OFF.

7.  Disconnect the Filter/Regulator.

8.  Close the in-line Shutoff Valve.

9.  Bleed air from the tool then disconnect the tool.

10. Drain the Filter/Regulator of water daily. With the 

unit under pressure, open the Drain Plug to expel 

any accumulated moisture from the Air Filter.

11.  Clean, then store the Filter/Regulator indoors.

Maintenance and Servicing

  Procedures not specifically explained in this manual must 

be performed only by a qualified technician.

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: 

Turn the Power Switch “OFF” and unplug the Filter/Regulator from its electrical outlet 

before performing any inspection, maintenance, or cleaning procedures.

TO PREVENT SERIOUS INJURY FROM FILTER/REGULATOR FAILURE: 

Do not use damaged equipment.  If abnormal noise or vibration occurs, 

have the problem corrected before further use.

Summary of Contents for 58547

Page 1: ...ired for assembly and service may not be included Read this material before using this product Failure to do so can result in serious injury SAVE THIS MANUAL Owner s Manual Safety Instructions Save Th...

Page 2: ...uctions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference The warnings precautions and ins...

Page 3: ...ned Air Filter Regulator Safety Warnings 1 Risk of bursting do not adjust Filter Regulator higher than marked maximum pressure of attachment 2 Risk of injury do not direct air stream at people or anim...

Page 4: ...uding all text under subheadings therein before set up or use of this product Note For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near the e...

Page 5: ...indered by undersized air supply components 4 Close the in line shutoff valve between the compressor and the tool 5 Turn on the air compressor according to the manufacturer s directions and allow it t...

Page 6: ...r Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler an...

Page 7: ...bration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of us...

Page 8: ...the tool s maximum air pressure at any time Turn the knob clockwise to increase the pressure and counter clockwise to decrease pressure Adjust the pressure gradually while checking the air output gaug...

Page 9: ...he Filter Regulator surface wipe with a damp cloth using a mild detergent or mild solvent Weekly Inspect Air Filter Quarterly every 3 months Tool Disassembly Cleaning and Inspection Have the internal...

Page 10: ...ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Parts List Part Description Qty 1 Tank 1...