Error type 

Possible causes 

Troubleshooting 

Controls within the reagent 

range.

 

Unexpected result of patient 

samples.

 

Reagent-related 

Reagent disintegration.

 

Is this the first of this delivery 

employed reagent? Is the 

storage temperature correct? 

 

Reagent-related 

Reagent disintegration. 

Don’t employ the reagent if the 

reconstituted storage life of the 

non-reconstituted reagent is 

expired.  

 

Reagent-related

  

Reagent disintegration due to 

too long heating in the reagent 

station. 

The reagent should not be 

stored in the analyser. When 

the test is completed remove 

the reagent from the 

instrument, close and store the 

reagent in compliance with the 

manufacturer’s instructions. 

 

Sample-related 

Contaminated reagent. 

Don’t touch the already 

dispensed samples / reagents 

with the pipette tip. 

 

Controls-related 

Disintegrated or contaminated 

material. 

Dissolve new controls. Incorrect 

reconstituted control 

materials(s)! Reconstitute the 

controls according to the 

manufacturer’s instructions. 

Only freshly deionised water 

may be used for the 

reconstruction. 

 

Analytical error 

Wrong reagent temperature. 

A suitable tube has to be used. 

Please note that only such a 

reagent volume may be 

dispensed into the tube that the 

filling height is not higher than 

the pre-heating station. Let the 

reagent come slowly to room 

temperature (within 15 – 20 

minutes). Some reagents 

(thrombin reagent for 

fibrinogen) may not be warmed 

up, but they should be brought 

to room temperature before 

use. Please follow the 

instructions of the reagent 

manufacturer. 

Summary of Contents for MC10 PLUS

Page 1: ...N U A L Instrument Manufacturer ABW Medizin und Technik GmbH Co KG Lagesche Str 15 32657 Lemgo Germany MC and MERLIN are registered trademarks of ABW Medizin und Technik GmbH Co KG IVD www merlinmedi...

Page 2: ...ed and liable to prosecution without prior allowance of ABW Medizin und Technik GmbH Co KG This applies especially for copying translating microfilming and storing and data processing in electronic sy...

Page 3: ...cs Device Operation manuals Biological risks MC 1 MC 4plus MC 10plus Consult instructions for use MC 1 MC 4plus MC 10plus LOT Batch code number Balls cuvettes Manufactured by MC 1 MC 4plus MC 10plus U...

Page 4: ...erformance test 15 3 2 1 Testing of a measurement resp of an incubation 17 3 3 Test parameter 19 3 4 Test evaluation calculation 21 3 4 1 Mechanical measurements ball method 21 3 4 2 Optical measureme...

Page 5: ...Handling of the cuvettes 43 7 3 Handling of the testing material 43 8 Quality control 44 9 Maintenance 44 9 1 Maintenance by user 44 9 2 System self test 45 9 2 1 Automatic self tests after switching...

Page 6: ...repair are excluded from this guarantee Defects which are a not within the period of guarantee and not communicated within one week after occurring to ABW b caused by chemical decomposition or corrosi...

Page 7: ...keeping until the detection of the coagulation is done automatically On the base of correct parameters and correct entering of the curves the coagulation times are converted into corresponding result...

Page 8: ...c the start reagent is added and the measurement is start simultaneously When the coagulation begins the growing clot pulls the ball out of the basic position and the magnetic sensor detects a magneti...

Page 9: ...ttes if required also employable as reagent pipetting station Pre heated storing position for start reagent pipette 2 Pipette storing position at room temperature 1 Drills 14 5 x 85 0 mm 5 for reagent...

Page 10: ...pettes can be used red storing position heated 5 Optical measuring position as option for diverse chromogenic tests 6 Signal lamps with activating keys depending on the condition of the system respect...

Page 11: ...e external power supply unit 3 Pipette sockets for the connection of automatic pipettes with contact line 4 RS 232 interface plug in for external printer 5 Barcode scanner connection for external barc...

Page 12: ...been pressed at the MC 10plus the time keeping can be started by pressing the pipetting key until the first stop 2 Pipette contact line For the connection of the automatic pipette with the analyser 3...

Page 13: ...and a measuring position activating key has been pressed at the MC 10plus the time keeping can be started by pressing the dispensing lever automatic pipette 2 Locking Filling lever For absorbing reage...

Page 14: ...11 4 Combitip Adjust volume of the combitips and adjust the sliding switch for volume selection no 3 to pipetting volume...

Page 15: ...000 Reagent tubes plastic 14 5 mm x 80 0 mm 832158 300 Coagulometer tubes plastic 833118 500 Thermo paper 851057 5 Accessories description Cat No Packing unit Automatic pipette Handystep with start ca...

Page 16: ...an area with low humidity and little variations in temperature The device should not be placed directly under ventilation shafts which cause strong draughts 3 Place the MC 10plus in an area which is...

Page 17: ...g Only the original external power supply 100 VAC 240 VAC which is delivered with the MC 10plus may be used otherwise the analyser could be damaged 2 6 Connection of the device 1 Connect the low volta...

Page 18: ...e Adjustment of date and system time Default Parameters Load default settings Software Version Language English German Chinese Print settings Print the settings of the settings menu Print result list...

Page 19: ...isplay After approx 15 sec the display changes automatically from the welcome display to the start menu The signal lamps do no longer light up Start menu Measure mode Test parameter Settings menu Pati...

Page 20: ...ts number one if an identification via Pat ID is required skip the next display Running number Test PT Input starting no 1 Confirm the input with the ENTER key Then you get automatically to the measur...

Page 21: ...s which is shown by blinking of the related display line and by the assigned now green blinking signal lamp When a measurement has been started in a measuring channel by using an automatic start pipet...

Page 22: ...the according measuring position key By pressing the key F3 on the keyboard all measuring positions can be reset simultaneously By pressing the F1 key you can switch on an automatic activation for th...

Page 23: ...log log lin Result unit sec g L sec sec Calibration value max min max min max min INR Calculation YES NO INR Std Value value2 ISI Value value3 Ball or optical method ball mechanical Single or double...

Page 24: ...f both single measurements does not exceed 6 as it is fixed in the regulations of the Federal Medical Association RILIB K If a parameter is carried out in general in double determination and if it has...

Page 25: ...urthermore the measured time of the PT can also be converted to the INR value Therefore it is necessary to have either the INR standard value which can be calculated by means of a self established cal...

Page 26: ...r 70 mOD there is a stop The concentration is calculated by comparison with a standard curve Clot 2 After the end of the start delay time a straight line horizontal is searched This straight line repr...

Page 27: ...s established after the timeout time The modification is displayed in mOD The concentration is calculated by comparison with a standard curve Test points of an optical clotting measurement measurement...

Page 28: ...ind of calculation resp measurement when entering the test parameters The correct test method is stated on the reagent package insert For questions please approach your contact person the reagent supp...

Page 29: ...are Version Language Print settings Print result list Barcode Scanner Online Setup Measure set up Quit 3 5 1 Date and time After selection of this point with the arrow keys and after confirming the se...

Page 30: ...rves and other parameter settings can by printed with an external printer For printing these settings please select this point with the arrow keys and confirm the print out by pressing the left arrow...

Page 31: ...your responsible IT manager ABW Fon 495261_927294 or a person in charge who has been instructed by the manufacturer 3 5 9 Measure setup When Suggest patient ID is displayed you can choose YES or NO I...

Page 32: ...lly to the input of the percentage increase of the waiting time whereas the probability of detecting also lowest fibrin concentrations is increasing Example Interval start 60 Sek Waiting time 10 6 75...

Page 33: ...of deletion depends on the internal laboratory organisation It is recommended to carry out the deletion procedure every morning before start of work Altogether up to 1 000 results can be stored whereb...

Page 34: ...he top and turn it to the right If the tip is not fixed at the pipette the precision can be affected negatively For fixing the tip on the automatic pipette accessory item the tip has to be turned to t...

Page 35: ...p pipette are employed Only combitips which are recommended for the according Handystep pipette should be employed Combitips with out of shape connection pieces should be removed Bent or otherwise dam...

Page 36: ...sample reagent flow constantly into the pipetting tip A slow absorption ensures that the correct volume gets into the tip A sudden release of the pipetting key may cause the absorption of a wrong volu...

Page 37: ...ormations and splashes the tip has to be positioned in such a distance to the bottom of the cuvette that it is in the sample at the end of the distribution procedure Alternatively you can hold the tip...

Page 38: ...s the tip has to be positioned in such a distance to the bottom of the cuvette that it is not in touch with the test material of the distribution procedure Alternatively you can hold the tip to the si...

Page 39: ...l and press the pipetting key into until the last stop The distribution should not be carried out so fast that the reagent splashes out of the cuvette In order to avoid a contamination of the reagent...

Page 40: ...elcome display to the start menu The signal lamps do no longer light up Start menu Measure mode Test parameter Settings menu Patient memory Service menu Select Measure mode by means of the arrow keys...

Page 41: ...umber one if an identification via Pat ID is required skip the next display Running number Test PT Input stsarting no 1 Confirm the input with the ENTER key Then you get automatically to the measuring...

Page 42: ...w orange 5 seconds before the end of the in the settings menu selected incubation time chapter 3 3 the MC 10plus signalizes acoustically the end of this step in order to remind to pipette the start re...

Page 43: ...The instrument automatically stops the measurement as soon as a clot is formed The signal display now lights up constantly red For preparing a new measurement press the activating key under the accord...

Page 44: ...ring positions simultaneously by pressing the F3 key reset of all measuring positions with the F3 key is not supported during automatic channel reset chapter 3 5 9 5 4 Measurement of parameters with t...

Page 45: ...ted directly under the measuring position but in the keyboard right from the right arrow key b A total sample reagent volume of at least 300 l has to be reached ifor ensuring a correct measurement Bef...

Page 46: ...If the measurement has been started mistakenly or the time keeping has not been stopped automatically for other reasons the measurement can be stopped at any time by inserting a new cuvette with ball...

Page 47: ...ENTION The instrument may not be connected to an extension lead ATTENTION The cuvettes are disposable items which may not be reused ATTENTION After positioning the cuvettes in the instrument the opera...

Page 48: ...e cuvettes have to be kept absolutely clean The cuvettes are designed for just one single use The balls in the cuvettes are made of special steel Purity weight size surface structure and magnetic prop...

Page 49: ...ure of the measuring pre heating block periodically with a usual calibrated thermometer The turning speed of the measuring cell can as well be checked from time to time with a calibrated stop watch A...

Page 50: ...ve is active again The error number 2000 is stored in the error list chapter 10 2 5 When changing into the measuring mode the ball sensors are inspected they have to be inactive then If this is not th...

Page 51: ...nical customer service of ABW Controls within the reagent range Unexpected result of patient samples Pre analytical error Sample tube under or overfilled Commercial vacuum tubes have to be filled comp...

Page 52: ...VIII Don t warm up the sample longer than 5 minutes at 37 C Sample related Wrong volume has been selected Follow the manufacturer s instructions Reagent related Contaminated reagent Reconstitute a new...

Page 53: ...s instructions Sample related Contaminated reagent Don t touch the already dispensed samples reagents with the pipette tip Controls related Disintegrated or contaminated material Dissolve new control...

Page 54: ...ered with manual Please practise the pipetting technique The instructions for the correct pipetting technique are in chapter 4 pipetting Wrong dispensing position it is very important that the reagent...

Page 55: ...losed when it is not used Sample related Wrong taking and handling of the samples Check the integrity of the sample Inspect it with regard to micro clots haemolysis or other problems Ensure that the r...

Page 56: ...mer insert a new cuvette with a new ball into the measuring cell Take the cuvette out of the measuring position after 10 seconds 9 2 System error If the instrument detects an error during its self tes...

Page 57: ...he printer buffer of the MC 10plus settings menu chapter 3 5 The lamp flashes when paper has to be reloaded The selected test determines what is printed out If PT has been selected the INR value and t...

Page 58: ...owing Instrument type Version Serial number Temperature measuring pre heating block Speed measuring cell Test location Test date Tester MC 10plus __________________________ __________________________...

Page 59: ...4plus MC 10 plus 1 Sicherheit EN 61010 1 Sicherheitsbestimmungen f r elektrische Mess Steuer Regel und Laborger te Allgemeine Anforderungen EN 61010 2 101 Sicherheitsbestimmungen f r elektrische Mess...

Page 60: ...54...

Reviews: