4.2 Auger Drive & Lockout
_
The proper operation of this auger requires that the operator pre-inspect the
drive system, know how to shut down the system in an emergency, and
generally monitor the system during operation.
Drive System and PTO Driveline:
Ensure that the PTO drive on the tractor is in
the o
ff
position before starting the tractor. Stay clear of PTO hazard area. Do
not exceed the maximum operation length of 34 inches of PTO driveline, or the
maximum angularity of 30 degrees.
Lockout/Shutdown of PTO Driveline:
Turn o
ff
engine. Remove ignition key
from tractor. If for some reason, you cannot remove the key, remove the PTO
driveline from the tractor.
4.3 Start Up & Break In
_
DANGER:
Electrocution Hazard! Make sure that all unauthorized personnel are clear
from the operation zone. This auger is not insulated. Be alert to overhead
obstructions and electrical wires. Electrocution can occur without direct
contact. Do not raise or lower auger until hazardous area is cleared. Failure
to maintain proper clearance can result in serious injury or death.
Have you completed the pre-operational checklist? If everything is satisfactory,
prepare for a 30 minute operation at half speed to break in your auger. Double
check that the intake hopper is properly positioned, and the PTO drive on the
tractor is in the o
ff
position.
NOTICE:
When starting the auger for the first time, be prepared for an emergency
shutdown in case of excessive vibration or noise. The auger may run
roughly until the tube is polished.
Start the tractor and idle at low RPM. Slowly engage the PTO driveline.