Page 17
still present, check to ensure that the monitor is ON and the video cable is
connected to the correct video port on the Rx module.
Problem:
Video image is dark
Action:
Check the iris control on the camera to ensure that it is open to the proper
amount for the conditions.
Problem:
Video image is too bright and appears overexposed
Action:
Check the Video overload indicator on the Rx module. If it is Red, the
video signal level is too high and the CCTV iris should be checked to ensure
that it is open properly for the conditions.
Problem:
No Data
Action:
Check that both transmit and receive modules is set to transmit/receive the
same data format (see section 5.0 for switch settings). Confirm that the data
connections are correct (see section 4.0 for data pinout connections). Check
to ensure that the data source is operating properly.
If the problem still persists after reviewing the above items, please contact Meridian
technical support (516- 285-1000).