background image

 

19 

 

Using the Download Site 

The landing page of the Download Site requires the user to enter a valid User Name and Password to 
authenticate user identity and permit entry to the Site.  These two codes are initially assigned by Meriam and 
can be found on a card included with shipment.  Locate the card and place in a safe place for future 
reference.   
 
Once a user is logged on to the Site, the 

Latest Release Notes

 screen appears listing and describing the most 

recent firmware releases posted and the posting date.  Individual files can be downloaded from the detailed 
description page of each DOF or firmware file listed.  Also available on this screen are the navigation 
buttons for 

Current Release Notes

File Download Area

, and 

Subscriber Options

 
The 

Current Release Notes

 screen describes the most recent firmware releases available and dates posted.  

Five (5) columns are shown on this page: Date, Title, Description, Manufacturer, Model.  These categories 
will assist the user in finding the release descriptions of the DOF, MFC Installer or MFC Firmware releases 
of interest.  Individual files can be downloaded from the detailed description page of each DOF or firmware 
file listed.  Each column can be sorted to assist searches of the release database. Also available on this screen 
are the navigation buttons for 

Latest Release Notes

File Download Area

, and 

Subscriber Options

 
The 

File Download Area

 screen is the actual download page.  Select from a list of downloadable firmware 

files (including MFx Installer Utility, MFC Firmware, MFC Documentation Firmware  
and DOF’s) by locating the file name of interest with the PC mouse and left clicking.  Dialog boxes guide the 
user through the process.  Multiple files can be downloaded using a Java applet that must first be loaded onto 
the host PC.  Dialog boxes again guide the user through the process.  Subsequent downloads of multiple files 
will be handled by the Java applet stored in the host PC memory.  Also available on this screen are the 
navigation buttons for 

Latest Release Notes

Current Release Notes

, and 

Subscriber Options

 

Subscriber Options

 

The 

Subscriber Options

 screen provides useful account information.  User Name and Password for the 

account are listed, as well as the subscription expiration date.  In addition, this screen allows the user to 
customize the account Password.  The user should also provide an e-mail address that allows Meriam to 
provide notification of new firmware updates, DOF releases, and subscription period expiration.  Press the 
“Update Subscriber Options” button to save all 

Subscriber Options

 changes. 

 
To report any difficulties with downloading operations, please contact Meriam Process Technologies at 
(216) 281-1100 or [email protected]
 
 

MFx Installer Utility 

 
MFx Installer utility should be loaded onto the host PC from the instruction manual CD (included with MFC 
shipment) or from the Meriam Download Site where it can be found on the 

File Download Area

 page.  MFx 

Installer coordinates the download operations from the host PC to the MFC.  Periodic improvements may be 
incorporated into this Utility.  Therefore, Meriam recommends periodic comparison of the MFx Installer 
version installed on the host PC to the latest available version on the Download Site to insure use of the an 
up to date Utility tool.

  

Directions for using MFx Installer are found under the Help Tool Bar selection. 

 

Summary of Contents for MFC 4101 HART

Page 1: ...icator MFC 4101 HART Communicator with Documentation MFC 4102 HART Communicator with Intrinsic Safety I S MFC 4103 HART Communicator with Documentation and I S OPERATOR INSTRUCTION MANUAL File No 4100...

Page 2: ...e Representatives button Contact Meriam Process Technologies directly by phone at 216 281 1100 or by e mail at meriam meriam com Direct all assistance inquiries to Technical Services HART is a registe...

Page 3: ...nging Lockout Code 8 Backlight off timer 8 Off Timer 8 Clock Edit 8 Enter PC Comm Mode 8 Battery Installation Removal all models 9 External Connections 9 DB 9 Connection 9 Hazardous Area Use 10 Intrin...

Page 4: ...e Download Site 18 Who may use 18 PC Requirements 18 Preparing the MFC for updating 18 Preparing to Download 18 Using the Download Site 19 Subscriber Options 19 MFx Installer Utility 19 Returning the...

Page 5: ...ay of the MFC 4100 is a 128 x 128 pixel graphic display with backlight Viewable area is 2 6 x 2 6 for 13 viewable message lines The display provides three types of information 1 header information inc...

Page 6: ...ween two separate functions as needed to facilitate data entry Soft key functions change depending on the present operating mode Soft key definitions are displayed at the bottom of the LCD just above...

Page 7: ...simply depress the key until the display returns to an acceptable level After adjusting Display Contrast wait at least five 5 seconds before turning unit off to insure storage of new contrast setting...

Page 8: ...are displayed at the bottom of the MFC display The following are examples or Soft Key definitions and their uses Up moves indicator arrow up one line in a menu list Down moves indicator arrow down on...

Page 9: ...of the MFC These keys are thumb operated and provide a convenient alternative to the Soft Key navigation buttons Side key functionality is not always available in the HART communication displays 3 Mu...

Page 10: ...properly connected HART device is setup for Multi drop loop or Burst Mode operation device address 0 The MFC will immediately initiate a multi drop poll to find all non zero addresses on the loop MFC...

Page 11: ...he Lockout Details screen listing all MFC parameters that can be protected by lockout see above left Individual functions can be locked or if preferred the lockout can be set to deny unauthorized acce...

Page 12: ...ess Select Scroll Up or Down to the auto shut off time desired Press Save to select the new value The shutoff timer can be disabled or set to shut off after time periods of from 1 minute up to 2 hours...

Page 13: ...s to MFC 1 AC Adapter The MFC 4100 can be powered by external AC Adapter connected to the jack located on the left side of the MFC P N A36742 bypasses the battery circuit to power the unit The battery...

Page 14: ...of the label is shown below WARNING Serious injury or death may result from explosions Do not make connection to the DB 9 connection port or to the AC adapter jack while in a hazardous area WARNING Se...

Page 15: ...ed to identify a field device by its model number and tag number and to read process data from the device This communication is referred to as polling The MFC 4100 can poll any Hart Device Second Comm...

Page 16: ...er up the MFC automatically detects if a field device is connect and attempts to establish HART communications When a device with address zero is found the MFC provides feedback to the user and starts...

Page 17: ...detected at the HART connection and the MFC is standing by to initiate communications The Device 0 On line message is shown 1 if a physical connection is made to a HART device after the MFC power is...

Page 18: ...t right provides information to help the user confirm the identity origin and save date time of the configuration Pressing Select again opens the configuration for review or offline editing New config...

Page 19: ...l Configs option The MFC will ask Delete ALL Configs ARE YOU SURE Select Yes to clear all stored configurations from memory Online Setup Mode Online Setup is the normal HART communication mode for the...

Page 20: ...on section of this manual 2 The Meriam DOF Device Library is missing or has become corrupted Without this DOF the MFC may not recognize a connected device Check the List Show DOFs menu option of Offli...

Page 21: ...ice using Universal and Common Practice commands to poll configure and maintain HART devices Specific functions supported include most polling tagging device configuration and trim operations for anal...

Page 22: ...r revisions of existing ones Who has access to the Download Site All MFC purchasers have unlimited access to the Download Site for six months from date of shipment These customers may download any pub...

Page 23: ...file name of interest with the PC mouse and left clicking Dialog boxes guide the user through the process Multiple files can be downloaded using a Java applet that must first be loaded onto the host...

Page 24: ...the Meriam Repair Department when you call fax or e mail your information An RMA number must accompany all incoming packages to insure proper tracking processing and repair work To assist us in proce...

Page 25: ...TRAST direct adjustment of display contrast in any mode automatic compensation for ambient temperature changes SECURITY LOCKOUT MFC 4100 Settings can be locked out entirely or by specific feature MEMO...

Page 26: ...le shoulder strap and HART lead compartment A36884 Adjustable detachable hanging strap inc d w MFC clips directly to MFC attach points A900614 00006 9 Volt Alkaline Battery inc d w MFC 2 req d A900614...

Page 27: ...23 Intrinsic Safety Control Document...

Page 28: ...ge Material Drain Vent Material Flange Type Remote Seal Isolator Material Flange Size Number of Remote Seals Remote Seal Fill Fluid Remote Seal Type HART Revision Device Revision Software Revision Fin...

Page 29: ...ll Fluid Gasket Material Flange Material Drain Vent Material Flange Type Remote Seal Isolator Material Flange Size Number of Remote Seals Remote Seal Fill Fluid Remote Seal Type Universal Revision Tra...

Page 30: ...Size Number of Remote Universal Revision Transmitter Revision Software Tag Date Descriptor Message ASC Model Ext SW Mode Revisions Const Mats Device ID Polling Address Request Preambles Burst Mode Se...

Page 31: ...ange Size Number of Remote Universal Revision Transmitter Revision Software Tag Date Descriptor Message ASC Model Ext SW Mode Revisions Const Mats Device ID Polling Address Request Preambles Burst Mod...

Reviews: