16
6. Interface specifications
6.1 RS422 control interface
In RS422 communication the Sphynx 2 must always be slave and the computer the master.
RS422 Pin out Sphynx 2:
Baud rate
19.2 Kbaud
Cable length:
<100 meter
Connector Type:
9 pole D-Sub Female
Pin 1: RX- (input)
Pin 2: RX+ (input)
Pin 3: TX+ (output)
Pin 4: TX- (output)
Pin 5: GND
Pin 6: NC
Pin 7: NC
Pin 8: NC
Pin 9: NC
For interfacing to the VScom/Easysync USB to RS422 I/O adapter a 1:1 male-femal 9 pin D-sub cable
must be used.
Pin 5
Pin 1
Pin 9
Pin 6
TDIF I/O Specifications:
Connectors:
1 x 25-pin female D-sub
Formats:
TDIF-1, TDIF96, TDIF DS
Sample Rates:
44.1 to 96 kHz
TDIF I/O Pin out:
The pin out format of the D25 connector is
compatible with the TDIF-1 specification.
Rear plate
The 8 channel TDIF I/O module makes it possible
to interface to equipment with a standard Tascam
TDIF interface. The module fully supports the
original TDIF 1 standard, the TDIF 96 extension
as well as the TDIF double speed format. The
module supports 8 channel I/O at 44.1 kHz or 96
kHz.
At 88.2 and 96 KHz the two TDIF interfaces are
required if the TDIF mode is TDIF-1 or TDIF 96. In
this case channel 1-4 is interfaced via connector
1, and channel 5-8 via connector 2.
Only a single interface connection is needed for
the TDIF DS mode, and in all three modes at 44.1
and 48 kHz sample rates.
TDIF mode is selected via DADman.
6.2 8 ch TDIF digital I/O module
TDIF
1
2
(Con. 1)
(Con. 2)
If you want to use an Antona RS232 to RS422
converter for controlling the Sphynx 2, you will
require a special cable between the Sphynx 2 and
the Antona converter.
Pin 1: GND
Pin 2: RX-
Pin 3: TX+
Pin 4: NC
Pin 5: GND
Pin 6: NC
Pin 7: RX+
Pin 8: TX-
Pin 9: +V
RS422 pin out for the Antona RS232 to RS422
converter in master mode: