Section 5 - Maintenance
Page 124
90-866938081 MAY 2009
Reference Electrode Wire of the MerCathode System
NOTICE
Washing the MerCathode assembly can damage components and lead to rapid
corrosion. Do not use any cleaning equipment such as brushes or high‑pressure washers
to clean the MerCathode assembly.
Do not pressure‑wash the reference electrode of the MerCathode assembly. Doing so
damages the coating on the reference electrode wire and decrease the corrosion
protection.
b
a
41163
a -
Anode
b -
Reference electrode (not visible in this view)
MerCathode Anode
CHECKING
Inspect the MerCathode anode and replace the anode if damaged.
b
a
41163
a -
Anode
b -
Reference electrode (not visible in this view)
REPLACING
Contact your Cummins MerCruiser Diesel Authorized Repair Facility.
MerCathode System Testing
If the boat is equipped with a Quicksilver MerCathode system, test the system to ensure
that it is providing adequate output to protect the underwater metal parts on the boat. The
test should be made where the boat is moored, using a Quicksilver Reference Electrode
and Test Meter.