350.020UK User Manual
Wiring Instructions
1.
Please use the installation cable supplied unless you need a greater distance between the
2 units. If you are extending the operating distance from 15m to up to 50m please use
an appropriate 4-core 0.5mm
²
diameter cable and from 50m up to 100m please use an
appropriate 4-core 0.75mm
²
diameter cable.
2.
When you are connecting the unit to an electric door or gate release please use an
appropriate 2 core 1.0mm
²
diameter cable.
3.
Connect wires 1,2,3 and 4 to both units respectively as highlighted in the diagram below.
4.
Terminals 5 and 6 on the indoor unit are to be used for an electric door release.
5.
Terminals 7 and 8 on the indoor unit are to be used for an electric gate release.
6.
Finally connect up the power supply to the indoor unit and hang it on its fixing bracket.
Cables:
1. Audio
2. Ground
3. Video
4. Power
Gate Release
Door Release
Mains Adaptor
Outdoor
Unit
Indoor
Unit