Mercury PR0018 User Manual Download Page 3

                                                                                        

 

 

 

  

Revision 2.2 

 

Page 3 of 14 

 

 

www.resourcedm.com 

Mercury Switch User Guide

 

 

Warning 

 
 
 
 
 
 

Please Note 

The specifications of the product detailed on this 
Set-Up  Guide  may  change  without  notice.  RDM 
Ltd. shall not be liable for errors or for incidental 
or consequential damages, directly and indirectly, 
in connection with the furnishing, performance or 
misuse of this product or document.

 

Ensure that all power is 
switched off before   
installing or maintaining 
this product 

The Mercury Switch 

 

From Resource Data Management 

 

Description 

 
The Mercury Switch (PR0018) is a device that allows up to 10 RDM Mercury controllers to be connected to an IP network, without the 
need for individual IP Futura modules. There are 10 RS232 connections for linking to 10 Mercury controllers. There are 3 standard 
Ethernet Switch (10/100baseT) connections for other network devices. The Ethernet ports are self configuring for uplinks and standard 
10/100 Base T device connections. 
 
As well as the Switch function there is the option for Island EEV control. This control can be achieved by using a transducer connected to 
the Mercury Switch 4-20mA input or from a remote Suction pressure reading sent across an IP network from a Mercury Plant Pack 
controller. Island trim heater control can also be achieved through the display port using a humidity temperature display (PR0445). To 
utilise either of these features then the PR0018-PHI build option would be required. 
 
Software version 2.2 and higher has the capability for CO2 Load shedding. 
See RDM Data Manager User Guides for more information on CO2 Load Shedding 
 

 

Front View 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Rear View 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Note:- 

The display port, mA input and mA input selector are fitted on the PR0018-PHI only.The mA input is available for Pressure 

applications only, for Humidity please use a PR0445 connected to the display por 

 

Top View 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

10 x RS232 Ports for direct connection to RDM controllers 

 

Mains connector 

3 x IP ports 

mA Input 

Display port 

mA input selector 

Summary of Contents for PR0018

Page 1: ...80 Johnstone Avenue Hillington Industrial Estate Glasgow Scotland G52 4NZ UK 44 0 141 810 2828 sales resourcedm com US OFFICE Resource Data Management Inc 100 North Sixth Street Suite 820C Minneapoli...

Page 2: ...Setup via Display 5 Recommended set up method 6 Set View Type 6 Set View Parameters This can also be achieved at the network front end 6 ID 6 Network Configuration 6 IP L Local IP Address 7 IP r IP Ad...

Page 3: ...This control can be achieved by using a transducer connected to the Mercury Switch 4 20mA input or from a remote Suction pressure reading sent across an IP network from a Mercury Plant Pack controlle...

Page 4: ...elf configuring Connection to a Data Manager Director Use a standard CAT5 patch lead and connect the Data Manager or Data Director to one of the 3 10 Base T ports 10 100 Base T connectors The three 10...

Page 5: ...splay The display fits a standard UK single socket pattress Enter Button Button used to enter confirm values after a change Up Button When in the software menu the up button is used to scroll up throu...

Page 6: ...ress Enter again to save the value The parameter list number will be displayed again Two other options are present in the parameter menu dFLt and ESC Selecting ESC will exit setup mode Selecting dFLt...

Page 7: ...ed by the DHCP server To configure the Mercury Switch for IP r set the two rotary switches to give each controller a unique identifier The controller should then be connected to the network 2 nEt From...

Page 8: ...to 0 5 0 to 7 2 0 1 Bar Psi 0 1 P 17 Evap 7 offset 0 0 to 0 5 0 to 7 2 0 1 Bar Psi 0 1 P 18 Evap 8 offset 0 0 to 0 5 0 to 7 2 0 1 Bar Psi 0 1 P 19 Evap 9 offset 0 0 to 0 5 0 to 7 2 0 1 Bar Psi 0 1 P 2...

Page 9: ...duced to a predetermined percentage A MOP alarm is also created See MOP P 41 MOP Diff When the pressure reduces below this value valves on controllers connected to the Switch will recover to their nor...

Page 10: ...perature 49 0 to 60 56 2 to 140 0 o C o F O 34 Remote 2 Temperature 49 0 to 60 56 2 to 140 0 o C o F O 35 Remote 3 Temperature 49 0 to 60 56 2 to 140 0 o C o F EEV Control Operation Product PR0018 PHI...

Page 11: ...ury Switch Or the remote Mercury Plant Controller The Mercury Case controllers require to have P17 Evaporator control set to 1 Remote for this feature to function Mercury Switch Type There are 4 types...

Page 12: ...et to Remote and the Data Manager GP timer channel directed to the Mercury Switch is in the on period the humidity control will operate as described above During the Data Manager GP timer channel off...

Page 13: ...to the Mercury Switch WebPages This can be achieved by using the Controller Info page in the Data Manager Data Director Find the IP address assigned to the Mercury Switch in question from the list Now...

Page 14: ...in Taiwan Ventilation There is no requirement for forced cooling ventilation Class 2 Insulation No protective Earth is required and none should be fitted The host equipment must provide a suitable ex...

Reviews: