Exhaust System
Page 6A-16
90-863758060 AUGUST 2006
EXHAUST ANGLE MEASUREMENT
Measure the exhaust angle of each section of the exhaust system using an inclinometer
as shown in the diagram below. Begin the measurement at the exhaust elbow outlet
continuing along each section to the exhaust exit point of the boat. All exhaust angle
measurements must be performed with the boat at rest in the water. Perform the first set
of measurements without a load in the boat. Perform the second set of measurements with
the boat fully loaded. See
Loading Requirements
.
a
b
c
18582
Typical exhaust (except 8.1L 496 cid.)
a -
Inclinometer
b -
Exhaust hose or tube
c -
Minimum 457 mm (18 in.)
a
b
8235
c
Typical exhaust 8.1L 496 cid.
a -
Inclinometer
b -
Exhaust hose or tube
c -
Minimum 457 mm (18 in.)
Boat Requirements
IMPORTANT: Consider the following requirements before performing the exhaust elbow
waterline height measurement. No prototype hulls or light layup hulls should be considered.
Any measurement performed on non‑production boats, prototype hulls, or light layup hulls
could be inaccurate and could result in product damage.
• All boats that display a CE certification capacity plate
must use the maximum
capacity as stated on the CE certification capacity plate to perform the exhaust
elbow waterline measurement.
Summary of Contents for 8.1S Horizon
Page 5: ...Page iv...
Page 19: ...Important Information Notes Page 1A 14 90 863758060 AUGUST 2006...
Page 53: ...Transmission and Drive Line Notes Page 2A 14 90 863758060 AUGUST 2006...
Page 59: ...Air Intake System Notes Page 4A 6 90 863758060 AUGUST 2006...
Page 119: ...Cooling System Notes Page 7A 22 90 863758060 AUGUST 2006...
Page 133: ...Electrical System Notes Page 8A 14 90 863758060 AUGUST 2006...
Page 153: ...Instrumentation and Controls Notes Page 9A 20 90 863758060 AUGUST 2006...
Page 163: ...Predelivery Preparation Notes Page 10A 10 90 863758060 AUGUST 2006...