Exhaust System
Page 6A-10
90-863758060 AUGUST 2006
• Every exhaust hose connection must be secured with at least two hose clamps. The
clamps should be stainless steel and at least 13 mm (½ in.) wide. Clamps that rely
solely on spring tension should not be used. (ABYC Standard)
• The system must have the capability to be serviced, reassembled and replaced while
maintaining all of the specifications. The boat builder must provide documentation such
as manuals, drawings, or orientation marks on production assemblies.
• It is strongly recommended that orientation marks be used on all production exhaust
system assemblies.
• In‑line mufflers, collectors, and hoses must self drain after engine shutdown.
T Junction With In‑Line Muffler
a
b
c
d
e f
g
h
i
k
j
g
l
15633
Typical
a -
Water line
b -
Minimum exhaust elbow height
with maximum load
c -
Exhaust back pressure check
point
d -
Resonator
e -
46 cm (18 in.) minimum between
exhaust elbow and collector
f -
10° downward slope minimum
g -
3° downward slope minimum
h -
30°–60° degree angle at T‑junction
i -
3° downward slope minimum
j -
Muffler
k -
External flappers
l -
Drain fitting
Summary of Contents for 8.1S Horizon
Page 5: ...Page iv...
Page 19: ...Important Information Notes Page 1A 14 90 863758060 AUGUST 2006...
Page 53: ...Transmission and Drive Line Notes Page 2A 14 90 863758060 AUGUST 2006...
Page 59: ...Air Intake System Notes Page 4A 6 90 863758060 AUGUST 2006...
Page 119: ...Cooling System Notes Page 7A 22 90 863758060 AUGUST 2006...
Page 133: ...Electrical System Notes Page 8A 14 90 863758060 AUGUST 2006...
Page 153: ...Instrumentation and Controls Notes Page 9A 20 90 863758060 AUGUST 2006...
Page 163: ...Predelivery Preparation Notes Page 10A 10 90 863758060 AUGUST 2006...