MINI PHOTOELECTRIC SMOKE
DETECTOR
Order ref: 350.127UK
User Manual
This compact unit detects initial smoke formation with its sensitive photoelectric system and signal
processing circuit giving an alarm signal as an early warning. Its reduced footprint makes it ideal for
smaller rooms where ceiling space is limited.
Specification:
Battery
3 x CR2450 button cell (supplied)
Alarm output
85dB/3m
Operation temperature
-10°C - 40°C
Quiescent current
≤10µA
Dimensions
37 x 72mmØ
Weight
75.6g
Installation:
1.
Choose an appropriate position to install the alarm on a ceiling away from obstructions.
2.
Use the screws and plugs provided to secure the installation panel securely to the ceiling.
3.
Align the 3 slots in the smoke detector with the 3 tags on the installation panel and rotate it
clockwise until it locks into position.
Testing and usage:
1.
Turn the smoke detector anti-clockwise to remove it from the installation panel.
2.
Remove the insulating tag from behind one of the batteries and ensure that all of them are securely
pressed into the housing.