Mercury Security Corporation, Copyright 2005

MR-10/20

             Doc. 10107-0000  rev. 1.03  3/05

  

                            

   Page 2

Information subject to change without notice.

6. TTL Interface:

The TTL interface has the standard 5-wire interface widely
used in the access control application. In addition, an input
to control the buzzer is provided. Cable with minimum of
24AWG wires should be used.

Pin #

Wire

Signal

Description

  1

Red

Vin

Power supply input, 5Vdc or 12Vdc, Model dependent

  2

Green

/Data (Mag) or

Reader data output

/Data 0 (Wieg)

  3

White

/Clock (Mag) or Reader data output
/Data 1 (Wieg)

  4

Brown LED

LED input
1-wire control: 0V turns on the green LED

          5V turns on the red LED

2-wire control: 0V turns on the red LED

  5

Orange Buzzer/LED

Buzzer/LED input:
1-wire control: 0V turns on the buzzer
2-wire control: 0V turns on the green LED

  6

Black

Signal Ground

Power supply return, DC ground

7. Grounding the Reader:

To avoid  having ESD (electrostatic discharge) interfering with the operation of the reader, the reader casing shall be
grounded. This can be accomplished by tying the mounting bracket to earth ground locally (e.g. grounded conduit).

8. DIP switch/Jumper setting:

The DIP switch/jumper on the MR-10/20 readers are used to select
a preset format. This preset format determines how the card is
interpreted, the functions for the LED and buzzer, and the output
signal format, etc. Refer to the format specification for detail. The
settings are for STANDARD models ONLY.

5. Weather Proofing the Reader:

The reader is rated to operate over an extended temperature range.
However, if the reader is expected to be exposed to weather, the
weatherized option (-OW) must be ordered. The option is imple-
mented in two parts. With the (-OW) option, the electronics is
conformal coated against moisture. A tube of dielectric grease is
supplied for the installer to coat field connections to complete the
procedure. After field connection/configuration is made, the grease
is to be applied on the DIP switch slides, keypad connection, and
the RJ-11 jack to seal out moisture.

Do not use sealant to seal reader case to the wall

. Doing so

will trap water in the reader and may cause damage to the reader.

MODULAR PLUG

1 (RED) +5 or +12Vdc

2 (GRN) DATA 0/DATA

3 (WHT) DATA 1/CLOCK

4 (BRN) LED

5 (ORG) BUZZER

6 (BLK) GROUND

depends on model

4 3

2 1

Summary of Contents for MR-10

Page 1: ... BEACH CA 90815 1755 562 986 9105 FAX 562 986 9205 CAUTION DONOTDISCONNECT KEYPADWITHOUTDISENGAGING THECONNECTOR 3 Reader Wiring The reader has a RJ 11 modular jack for easy field connection A small piece of pre terminated cable is supplied with each standard reader for field wiring The pre terminated cable has nonstandard color Refer to pin number if the pre terminated cable is not used Cable wit...

Page 2: ...tying the mounting bracket to earth ground locally e g grounded conduit 8 DIP switch Jumper setting The DIP switch jumper on the MR 10 20 readers are used to select a preset format This preset format determines how the card is interpreted the functions for the LED and buzzer and the output signal format etc Refer to the format specification for detail The settings are for STANDARD models ONLY 5 We...

Page 3: ...tRange 34 bitRange 8 1 3 000 255 000 999 4 8 00000 65535 00000 99999 9 1 3 000 255 000 999 4 9 000000 065535 000000 999999 10 1 4 0000 0255 0000 4097 5 10 000000 065535 000000 999999 11 or more 1 5 00000 00255 00000 04097 6 11 000000 065535 000000 999999 AMC card 1 6 000000 000255 000000 004097 7 12 000000 065535 000000 999999 Format 6 26 bitWiegandcompatibleoutputfromstandardNorthernComputer32 bi...

Page 4: ...ed to verify the LED function and the buzzer input for the buzzer function For the MR 20 thereaderwillechoakeypresswithabriefflashofbothLEDsandashortbeepofthebuzzer Resettotherequired format for normal operation after test 12 Maintenance The readers are designed to provide continuous service with minimal routine maintenance However contaminants such as magnetic oxides from badges and dirt tend to ...

Page 5: ...ie cast aluminum gray powder coat standard Mounting stainless steel Wall plate 18 CRS gray powder coat standard Card 75 bpi ANSI X4 16 Track 2 standard Speed 3 to 50 ips ReadHead 1 000 000 passes typical standard Distance 500 152m with 18 AWG wires Environmental Temperature 55 to 85 degrees C storage 40 to 75 degrees C operating Humidity 0 95 RHNC standard 100 OW option 14 Product Identification R...

Page 6: ...or representative to make any other warranties or implied warranties and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose Returned units are repaired or replaced from a stock of reconditioned units Returns must be accompanied by a return authorization number RMA obtained from customer service and prepaid postage and insurance Liability ...

Reviews: