Mercury Security © 2015
EP1502
DOC 10107-0031
REV 1.06
Page 1
www.mercury-security.com
2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562)986-9105 FAX (562) 986-9205
EP1502 Intelligent Controller
with Two Reader Interface
Installation and Specifications:
1. General:
The EP1502 intelligent controller provides decision making, event reporting, and database storage for the
Mercury hardware platform. Two reader interfaces provide control for two physical barriers.
The EP1502 communicates with the host via on-board 10-BaseT/100Base-TX Ethernet port. Alternatively,
port 1 (RS-232) can be used for host communication.
Each reader port can accommodate a reader that utilizes TTL (D1/D0, Clock/Data), F/2F, or 2-wire
RS-485 device signaling, and also provides tri-state LED control, and buzzer control (one wire LED mode
only). Four Form-C relay outputs may be used for strike control or alarm signaling. The relay contacts are
rated at 5 A @ 30 Vdc, dry contact configuration. Eight inputs are provided that may be used for monitoring
the door contacts, exit push buttons and alarm contacts. Input circuits may be configured as unsupervised
or supervised. The EP1502 requires 12 to 24 Vdc for power.
2. EP1502 Hardware:
J4
J3
1
2
3
TMP
FLT
R1
R2
+
1
3
2
4
J8
R
ESE
T
S2
BT1
3V BR/CR2330
J1
5V
3.3V
2
3
4
1
S1
VBAT
IN1
K
1
K
2
K
3
K
4
K2
K1
K3
K4
IN2
IN3
IN4
IN5
IN6
IN7
IN8
8V
J6
J2
J5
J7
PASS
12V
GND
DAT
D0
TB8
R
EA
D
ER
1
BZR
VO
GND
FLT
GND
TMP
GND
VIN
TB1
LED
D1
CLK
R
EA
D
ER
2
D1
LED
VO
BZR
GND
CLK
D0
DAT
TB9
NO
OUT 1 C
NC
NO
OUT 2 C
NC
NC
OUT 4 C
NC
NO
NO
OUT 3 C
TB
10
TB
11
RXD
CTS
GND
RTS
TXD
TB2
TB
3
TR+
GND
TR-
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
TB4
TB5
TB6
TB7
.25 [6.35]
5.50 [139.70]
.25 [6.35]
6.00 [152.40]
.50 [12.70]
2.00 [50.80]
3.00 [76.20]
2.00 [50.80]
.50 [12.70]
8.00 [203.20]
Ø.156 [3.96]
8 PLACES
RESET SWITCH
BATTERY: BR/CR2330
REPLACE ANNUALLY
-
STATUS LED's
DIP SWITCHES
RELAY
STATUS
LED's
INPUT
STATUS
LED's
CHASSIS
GROUND
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must
accept any interference received, including interference that
may cause undesired operation.