Drawing 1 mcr BORA L, O 

 

Fan 

ØD 

[mm] 

L

 

[mm] 

Lc 

[mm] 

[mm] 

Hc 

[mm] 

[mm] 

[mm] 

[mm] 

[mm] 

[mm] 

[mm] 

[mm] 

mcr Bora 290 

290 

2000 

2410 

317 

329 

472 

400 

610 

580 

167 

26 

12 

mcr Bora 315 

315 

2000 

2410 

342 

354 

472 

400 

610 

580 

167 

26 

12 

mcr Bora 355 

355 

2000 

2410 

377 

389 

517 

400 

644 

614 

167 

26 

12 

mcr Bora 380 

380 

2000 

2410 

407 

419 

557 

400 

644 

614 

167 

26 

12 

mcr Bora 400 

400 

2000 

2410 

427 

440 

607 

400 

694 

664 

167 

26 

12 

mcr Bora 450 

450 

2000 

2410 

482 

495 

657 

400 

750 

720 

167 

26 

12 

mcr Bora 500 

500 

2650 

3060 

533 

547 

708 

480 

780 

750 

200 

30 

14 

mcr Bora 560 

560 

2650 

3060 

608 

622 

798 

650 

950 

920 

255 

30 

14 

 

7. INSTALLATION_____________________________________________ 

The mcr Bora smoke exhaust jet fan is intended for use in rooms designed for moving air and fire gases 
(in the fire zone). 
 

7.1. Pre-assembly inspection____________________________________________________ 

Each smoke exhaust fan is factory inspected by the manufacturer prior to packing and shipping. Upon 
unpacking the delivered smoke exhaust fan, visually examine it for any damage in transport.  
The motor shaft should rotate with the rotor without evident resistance or scraping. 

Summary of Contents for mcr Bora BO

Page 1: ...Ul Grzegorza z Sanoka 2 80 408 Gdańsk tel 0 58 341 42 45 tel fax 0 58 341 39 85 OPERATIONAL AND MAINTENANCE MANUAL Jet fan mcr Bora Revision 19 06 27 4 FIRE VENTILATION SYSTEMS ...

Page 2: ...e 4 4 3 Versions 5 5 IDENTIFICATION MARKINGS 5 6 DESIGN AND OPERATING PRINCIPLE 5 6 1 Design 5 6 2 Function 5 6 3 Dimensions and technical features 5 7 INSTALLATION 7 7 1 Pre assembly inspection 7 7 2 Location and assembly 7 7 3 Electrical connections 7 7 4 Commissioning 8 8 TRANSPORT STORAGE CONDITIONS 8 9 SAFETY MANUAL 9 10 MAINTENANCE SERVICING 8 11 WARRANTY TERMS CONDITIONS 9 FAN MEASUREMENT R...

Page 3: ...st fans The design also meets the state of the art in technology while assuring health and safety protection 2 MANUFACTURER S DISCLAIMER__________________________________ The manufacturer shall not be liable for any consequences of non intended use or misuse of the equipment DO NOT install any components that are not included in the equipment composition or accessories Unauthorised modifications o...

Page 4: ...re occurance The available versions include single direction fans with dual speed motor reversible fans with dual speed motor The fans can be installed indoors on suitable consoles with the motor in the horizontal orientation The operating temperature range for fans in general purpose ventilation systems is 20 C to 40 C The fan may force dry air only with a maximum particulate content of 0 3 g m T...

Page 5: ...ing assembly and silencers The motor is coupled directly to an aluminium rotor on bearings and on the rotor the profiled blades are installed The angle and number of blades depend on the required thrust and capacity of the fan The motor bearings are high temperature resistant and maintenance free On the inlet and outlet side the engine is connected to silencers The medium which is fire gases and a...

Page 6: ...00 2410 482 495 657 400 750 720 167 26 12 mcr Bora 500 500 2650 3060 533 547 708 480 780 750 200 30 14 mcr Bora 560 560 2650 3060 608 622 798 650 950 920 255 30 14 7 INSTALLATION_____________________________________________ The mcr Bora smoke exhaust jet fan is intended for use in rooms designed for moving air and fire gases in the fire zone 7 1 Pre assembly inspection_____________________________...

Page 7: ...g through the gland and into the terminal box on the fan casing then connect the wiring to the terminals in accordance with the diagram shown in the box The electrical wire with the proper fire resistance rating is installed in standard by the manufacturer between the fan motor and the terminal box Each fan motor must be connected to the electrical power system through an overcurrent switch The sa...

Page 8: ...omponents of the fan and or its motor the maximum relative humidity is 80 at 20 C the ambient temperature is between 20ºC and 40ºC no vibrations are present 9 SAFETY MANUAL________________________________________________ Read and understand this Operating and Maintenance Manual before commissioning and servicing the product The smoke exhaust fan is not hazardous when firmly attached to a ventilati...

Page 9: ... or sales contract subject to Item 10 5 MERCOR SA has the right to extend the time of repair if the defect removal is complicated or requires purchase of custom components or spare parts 6 The warranty liability only covers all defects arising from causes present in the equipment at the date of sale 7 Defects caused by improper operation or otherwise as listed in Item 10 herein the buyer warranty ...

Page 10: ...this Operating and Maintenance Manual and or good construction practice The equipment and or parts thereof with removed or damaged nameplate rating plate and or warranty seals 11 The buyer warranty rights holder is required to operate the equipment properly and carry out technical inspection and maintenance in accordance with the section MAINTENANCE AND SERVICING in the following Operating and Mai...

Page 11: ...ent draw in steady state operation of the equipment MEASUREMENT RESULTS A U1 V1 W1 U2 V2 W2 NOTES Full name of the measuring technician Date measured Signature Return this Report immediately after completion of measurements to MERCOR SA Fire Ventilation Systems ul Grzegorza z Sanoka 2 80 408 Gdańsk and not later than within 8 weeks from the date of equipment purchase equivalent to the date of the ...

Reviews: