background image

FW & NW Series Ops Manual 

EZ TUBE INSTALLATION AND REPLACEMENT INSTRUCTIONS 

 

 

CAUTION:  PRIOR TO REPLACING A HEAT TUBE, MAKE SURE THE CONTACT IS CLEAN. 

IF IT IS BURNT OR DIRTY REPLACE THE SOCKET.

 

 

 

 

 

 

 

 

 

 

NOTE:  These instructions are based on the unit laying on a work surface upside down. 

 

CAUTION:  Be sure the tube is centered in the socket terminals before placing the warmer in the 

upright position and turning on power. 

1. Remove the tube guard by pushing against the face of 

the warmer with left thumb and “bowing” the cross brace 

upward with your right hand.  Pull the brace free.  

Remove the lengthwise brace. 

2. Place the left tip of the tube under the white 

socket (receptacle of the terminal).  Raise the tube 

into the slot and apply enough inward pressure to 

compress the terminal slightly. 

3. While keeping the tube compressed into the left 

terminal of the socket, position the right end of the tube 

directly beneath the right socket. 

4. Raise the tube into direct alignment with the 

center of the right terminal.  Release grip slowly 

allowing the compressed left socket (terminal) to 

lock tube into position. 

Summary of Contents for FW Series

Page 1: ...ible concealed shipping damage If unit is found to be damaged save all packing materials and contact your delivery carrier within 5 days Refer to Shipping Damage Instructions enclosed for detailed instructions Failure to follow these instructions will negate Merco Savory s or your ability to file claims and receive compensation for shipping damage TO BE SERVICED ONLY BY AUTHORIZED PERSONS ...

Page 2: ... If your unit was supplied with appliance lamps they are teflon coated When replacing these bulbs they must be replaced with similarly coated bulbs This is mandatory to comply with NSF regulations These bulbs may be purchased from one of the Merco Savory authorized maintenance and repair centers TEMPERATURE ADJUSTMENT Standard Merco Food Warmers The standard unit comes only with an on off toggle s...

Page 3: ...For units with an infinite control both ends of the heat tube will have wire nuts 4 Carefully remove the end panel remove the on off switch and disconnect the white wire Remove the wire nut from the opposite end of the heat tube The tube is now ready to be taken out of the unit 3 Remove the hex head retaining nut from the on off switch Remove the 3 screws holding the end panel onto the unit switch...

Page 4: ... against the face of the warmer with left thumb and bowing the cross brace upward with your right hand Pull the brace free Remove the lengthwise brace 2 Place the left tip of the tube under the white socket receptacle of the terminal Raise the tube into the slot and apply enough inward pressure to compress the terminal slightly 3 While keeping the tube compressed into the left terminal of the sock...

Page 5: ... Limited Warranty and any responsibility or obligations associated therein null and void This includes any damage costs or legal actions resulting from the installation of any Merco commercial cooking equipment in a non commercial application or installation where the equipment is being used for applications other than those approved for by Merco LIMITATIONS OF LIABILITY The preceding paragraphs s...

Page 6: ...FW NW Series Ops Manual 6 This page intentionally left blank ...

Page 7: ...FW NW Series Ops Manual 7 This page intentionally left blank ...

Page 8: ...W Series Ops Manual 8 Merco Savory LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Telephone 260 459 8200 Facsimile 260 436 0735 Service Hotline 800 678 9511 www mercosavory com ...

Reviews: