Mercia Garden Products 0619LOG001-V4 General Instructions Manual Download Page 2

2

1

3

4

5

6

7

8

9

10

11

13

14

17

18

Storm Brace - 27x44x2000mm QTY 8

F2744-2000

19

20

15

16

21

P 2

0619LOG001-V4

Overall Dimensions:

Width = 2614mm 

Depth = 2024mm 

Height = 2542mm

Base Dimensions: 

Width = 2304mm 

Depth = 1803mm 

Please retain product label and instructions for future reference

Before assembly  

please make sure you have a 

suitable base ready to erect your 

building 

 

MADE IN GREAT BRITAIN

Short Window Pack*

QTY 1

Single Door Pack*

LOG 001 Gable - 2500mm

QTY 2

Starter Board - 19x66x2500mm QTY 2

LB19RT66-A-2500

Log Board - 19x120x1370mm QTY 6

LB19-B-1370

Log Board - 19x120x310mm QTY 30

LB19-B-310

Log Board - 19x120x310mm QTY 12

LB19-C-310

Log Board - 19x120x2500mm QTY 19

LB19-A-2500

Log Board - 19x120x2000mm QTY 38

LB19-A-2000

Log Board - 110x19x2000mm QTY 2

LB19RG110-A-2000

Roof Purlin - 40x90x2004mm QTY 3

F4090-A-2004

Fascia - 16x120x1347mm QTY 4

S16120-1347

Eaves Frame - 44x27x2000mm QTY 2

F2744-2004

Roof Board - 121x16x1344mm QTY 38

MB16-C-1344

Floor Board - 121x16x2264mm QTY 16

MB16-C-2264

Bearer - 44x44x2304mm QTY 2

F4444-2304-PT

Bearer - 44x44x1715mm QTY 9

F4444-1715-PT

Log Board - 120x19x2500mm 

LB19-AD-2500

*All components for the Windows and Doors are 

shown in the Windows and Doors instruction packs.

Felt

12

Closure Trim - 16x28x2400mm (approx length) QTY 8

S1628-2400

Summary of Contents for 0619LOG001-V4

Page 1: ...ine and sheltered as much as possible during rain or snow BUILDING A BASE When thinking about where the building and base are going to be constructed Ensure that there will be access 60cm to all sides...

Page 2: ...mm QTY 6 LB19 B 1370 Log Board 19x120x310mm QTY 30 LB19 B 310 Log Board 19x120x310mm QTY 12 LB19 C 310 Log Board 19x120x2500mm QTY 19 LB19 A 2500 Log Board 19x120x2000mm QTY 38 LB19 A 2000 Log Board 1...

Page 3: ...60mm Bolt Set x16 P 3 Please retain product label and instructions for future reference Pre assembly Please note Each board interlocks at either end in a staggered pattern Before securing ensure that...

Page 4: ...led base frame along the longest sides Ensure the notches at either end of each board are flush and level with the ends of the frame Fix each of the starter boards to the frame by screwing through the...

Page 5: ...the boards are level and flush with each other as you lay each one Doors can be hung once the boarding has enclosed the door frame by 12 13 boards refer to door installation instructions if not you ca...

Page 6: ...er boards and rest on to the longer board Ensure the boards are level with each end Please note This image is for illustrative purposes and may differ from your choice in product regarding window posi...

Page 7: ...TY 38 Place the first two roof board s No 15 onto the assembly on each side making sure the boards are flush to the end of the roof purlin Once in position fix to each purlin using 3x40mm screws Ensur...

Page 8: ...oor boards internally making sure to interlock each individual board Do NOT secure the boards until the last board has been measured and cut Following the same method outlined previously measure the g...

Page 9: ...crew trim to fit Step 15 Parts needed No 12 QTY 4 Inside the building place the closure trim No 12 against the boarding and align with the roof as shown in the illustration ensuring the angled face fo...

Page 10: ...40mm Screws Pre drill hole 40mm screw 14 14 14 14 IMPORTANT Pre drill before fixing screws 19 19 Pre drill hole 60mm bolt Step 19 Parts needed No 19 QTY 8 Arrange the storm braces No 19 around the bui...

Reviews: