background image

Please retain product label and instructions for future reference

             

P 8

Cut four strips from the roll of 

felt 

(No.26):

2 x 430cm (L) X 100cm (W) 

1 x 350cm (L) X 100cm (W) 

1 x 150cm (L) X 100cm (W)

Place the felt on top of the roof 

and align as shown in diagram 

ensuring each strip overlaps 

the next by 20cm. Ensure all 

strips over hang roof by 5cm. 

Ensure strip 1 is the first piece 

placed down then lay sheet 2, 3 

and then 4 on top. 

Cut the sides as shown in 

diagram at the dotted lines, use 

fascia width as guide  for 

overhang. 

Fix each sheet using felt tacks 

along where sheet overlap.

Use felt tacks at 100mm 

intervals.

200x10mm felt tacks

Step 15

HANDLE

WITH CARE

1

2

3

4

100cm

20cm

20cm

20cm

5c

m

5c

m

5c

m

430cm

350cm

150cm

1

2

3

4

5c

m

28

28

28

28

Please note:

 It is advisable to place a board across the length of 

the roof to kneel on whilst felting.

Felt 

tacks 

Step 16

Fit the front cover trims (

No. 25) 

to 

the panel joins either side of the 

door panel using  3x40mm screws 

for each trim.

Fit a further two to the ends of the 

gable panels at the edge of the 

window panels using 3x40mm 

screws for each trim.

12x40mm Screws

Pre drill 

hole

40mm 

screw

25

25

25

25

Summary of Contents for 03TGCOR0909DDFW-V1

Page 1: ...extended periods of warm sunshine and sheltered as much as possible during rain or snow Once your garden building has been installed it will need to be treated as soon as possible and annually to prev...

Page 2: ...03TGCORPGR1417X2017 V1 Large Gable Left QTY 1 AI 03TGCORPGL1389X2094 V1 Small Gable Left QTY 1 AI 03TGCORPGL1417X2017 V1 Large Roof QTY 1 AI 03TAGROOF1685X2889 V1 Small Roof QTY 1 AI 03TAGROOF1204X288...

Page 3: ...PI 07 0114 Press Lock QTY 1 PI 07 0162 Rounded Butt Hinge QTY 6 PI 07 0066 L Bracket QTY 2 PI 07 0012 Chrome Handle QTY 2 PI 07 0081 Turn Button QTY 2 PI 07 0034 34 35 Locating Block 28x28x239mm QTY 2...

Page 4: ...the doors using 25mm screws Ensuring the doors are positioned equally fix the hinges to the door panel using 30mm screws 18x25mm Screws 18x30mm Screws Pre drill hole 2 11 12 31 30mm screw 25mm screw...

Page 5: ...corners together with 3x 60mm screw a shown in diagram Do not fix the panels to the floor untill the roof has been fitted 3x60mm Screws c Pre drill hole 60mm screw 5 17 Pre drill hole Step 7 Place the...

Page 6: ...e framing sits flush with the gable framing and fix in place with 4x50mm screws Place the front right window framing No 19 on top of the window panel opposite the left gables ensure the framing sits f...

Page 7: ...n the illustration using 6x30mm screws Ensure to fix the framing the opposite direction to the roof bearers Fix the locating blocks No 35 to the opposing sides to the roof framing these blocks are to...

Page 8: ...e fascia width as guide for overhang Fix each sheet using felt tacks along where sheet overlap Use felt tacks at 100mm intervals 200x10mm felt tacks Step 15 HANDLE WITH CARE 1 2 3 4 100cm 20cm 20cm 20...

Page 9: ...s No 22 to the window sides of the building using 3x40mm screws per fascia Fit the fascia No 21 to the front of the building using 3x40mm screws 19x40mm Screws Step 18 22 40mm screw Pre drill hole 22...

Page 10: ...refuly peel covering back Step 21 Attach the remaining rain guard No 14 above the doors fixing in place using 3x60mm 3x60mm Screws 60mm screw 14 14 Pre drill hole Step 22 On the inside of the building...

Page 11: ...2 1 3 4...

Page 12: ...1 2 REGISTER FOR YOUR ANTI ROT GUARANTEE TODAY PLEASE SCAN HERE...