Mercia Garden Products 02DORM0707-V3-PEFC General Instructions Manual Download Page 2

P 2

02DORM0707-V3

Overall Dimensions:

Width = 2183mm 

Depth = 2236mm 

Height = 2377mm

Base Dimensions: 

Width = 2077mm 

Depth = 2067mm 

Please retain product label and instructions for future reference

             

Before assembly  

please make sure you have a 

suitable base ready to erect your 

building 

 

MADE IN GREAT BRITAIN

1

2

3

4

5

6

7

8

9

Veranda

Floor

Floor

Door Panel

Window Panel

Left

Window Panel

Right

Rear Panel

Veranda Front 

Panel

Door Gable

Top

Plain Gable

Top

10

11

12

13

Roof Panel

Window Roof 

Panel

Sml Bunk

Floor

Lrg Bunk

Floor

14

15

16

17

Dorma Window 

Panel

Dorma Left 

Panel

Dorma Right 

Panel

Dorma Roof 

OSB 

18

Rail End

20

Safety

Rail

19

Door

21

22

Ply Triangle

“L” Bracket

23

24

Door Handle

Hinge

25

QTY x4

Window 

AI-02PHOW-V1

PI-07-0011

Window Block

QTY x10

26

27

28

QTY x2

QTY x2

QTY x2

Double Window 

Fixing Kit

Floor Joining Blocks - 200mm QTY 5

Fascia Blocks - 140mm QTY 6

Window Felt Trim - 742mm 

Eaves Frame - 670mm QTY 2

Long Cover Trim - 1594mm QTY 2

Short Cover Trim - 361mm QTY 2

Felt Trim - 790mm QTY 2

Ridge Bar - 843mm 

29

30

31

32

33

34

35

36

AI-02DORMVF2067X983-V3

AI-02DORMBFF1015X1979-V3

AI-02DORMRWP681X642-V3

AI-02DORMRWLS725X502-V3

AI-02DORMRWRS725X502-V3

PI-03-0129

AI-02DORMSR937X981-V3

AI-02DORM0707-V3D

AI-02DPHW-V1

Window Cross

PI-04-0013

QTY x6

AI-02DORMSR623X922-V3

PLY TRIANGLE

PI-07-0012

PI-04-0024

PI-07-0013

FS2828-200mm

FS2828-140mm

S1230-742mm

FS2828-670mm

S1256-1594mm

S1230-790mm

S1256-361mm

F2744-863mm ANGLED

AI-02DORMF2060X1080-V3

AI-02DORMDP1979X1264-V3

AI-02DORMWSL1991X1621-V3

AI-02DORMWSR1991X1621-V3

AI-02DORMPG2067X1594-V3

AI-02DORMDP1979X1264-V3

AI-02DORMDGT2067X741-V3

AI-02DORMPGT2067X741-V3

AI-02DORMROOF2158X1365-V3

AI-02DORMWINROOF2158X1365-V3

AI-02DORMBFR1064X1040-V3

Summary of Contents for 02DORM0707-V3-PEFC

Page 1: ...welling of the wood panels may occur Warping of the wood may also occur during excessive dry spells due to an interior moisture loss Unfortunately these processes cannot be avoided but can be helped It is suggested that the outdoor building is sprayed with water during extended periods of warm sunshine and sheltered as much as possible during rain or snow Our buildings are pre treated with a water...

Page 2: ...0 26 27 28 QTY x2 QTY x2 QTY x2 Double Window Fixing Kit Floor Joining Blocks 200mm QTY 5 Fascia Blocks 140mm QTY 6 Window Felt Trim 742mm Eaves Frame 670mm QTY 2 Long Cover Trim 1594mm QTY 2 Short Cover Trim 361mm QTY 2 Felt Trim 790mm QTY 2 Ridge Bar 843mm 29 30 31 32 33 34 35 36 AI 02DORMVF2067X983 V3 AI 02DORMBFF1015X1979 V3 AI 02DORMRWP681X642 V3 AI 02DORMRWLS725X502 V3 AI 02DORMRWRS725X502 V...

Page 3: ...95 1960mm F4444 288mm Nail Bag Felt Tacks x 140 30mm Black Screw x 16 30mm Screw x 100 40mm Screw x 74 50mm Screw x 90 60mm Screw x 5 70mm Screw x 30 25mm Screw x 12 20mm Screw x 30 Beading 9x12x203mm QTY4 50 51 BEADING 9X12X203mm Pre Assembly Before assembling remove the transportation blocks from the bottom of each panel Step 1 To fix the Windows No 21 No 22 into the panels that accomodate a win...

Page 4: ...ng water can collect See front page on base requirements 10x30mm Screws 30mm screw Pre drill hole Step 4 Attach the Rear Panel No 6 the Right Window Panel No 5 at the corners using 3x50mm screws as shown in the diagram DO NOT secure to the floor until the roof is fixed and the building is square 3x50mm Screws 50mm screw Pre drill hole Step 5 Attach the rear panel the Left Window Panel No 4 and the...

Page 5: ...m screws as shown in diagram 4x50mm Screws 50mm screw Pre drill hole Step 8 Place the Door Gable Top No 8 onto the Veranda Front Panel No 7 ensuring the cladding and framing on either side is flush see diagram Fix with 4x50mm screws as shown in diagram 4x50mm Screws 50mm screw Pre drill hole Step 9 Fix both the Window Roof No 11 and the Plain Roof No 10 as illustrated making sure both roofs fit ev...

Page 6: ...crew from the outside of the building Place the Rail End No 18 into position ensure overhang is flush against the Bunk Floor Fix to the Bunk floor and to the side panel using 6x50mm screws and secure to through the roof panel with 4x30mm screws 4x30mm Screws 8x50mm Screws Pre drill hole 30mm screw 50mm screw Step 13 Place the Safety Rail No 19 up against the Rail End No 18 and fix to the Bunk Floo...

Page 7: ...p 16 The next step is to fit the Ladder Hand Rails First attach the Right Hand Rail No 39 to the Rear Panel using 4 x 50mm screws pre drill holes first and make sure the screws are fixed into the Rear Panel framing Next fix the Left Hand Rail No 40 to the side of the Bunk Floor Safety Rail using 2x 50mm screws make sure to pre drill holes first Then attach one of the Hand Rail Supports No 41 to th...

Page 8: ... inbetween the Dormer Window No 15 and the Roof Ensure the flat edge is against the Dormer Window panel and the angled edge is resting on the Roof Secure in place using a corner brace No 25 at one end with 4x30mm screws Fix the angled side with 1x50mm screw fixing through the Support Bar into the boards 4x30mm Screws 1x50mm Screws 30mm screw Pre drill hole 50mm screw Step 20 Fix the Dormer Roof Sh...

Page 9: ... Panels at the front and back of the building Fix another two to the dormer roof sheets ensure the blocks touch 12x40mm Screws 50mm screw Pre drill hole Step 23 Cut the Felt into 6 sheets see illustration for dimensions and lay onto the roof as shown in the diagram ensuring there is a 50mm overhang around the sides Fix using 140x felt tacks 140x Felt Tacks 2nd 770mm 190mm rd 3 1000mm 460mm 1220mm ...

Page 10: ...Trims No 34 to either side of the pretruding window using 3x 30mm screws per trim Secure the Window Felt Trim No 31 as shown in the illustration using 3x 30mm screws 9x30mm Screws 30mm screw Pre drill hole Step 27 Place a Window Cross No 23 against the inside of each window Position the frame centrally to the window and fix in place using 4x20mm screws Place the Wooden Door Handle No 26 on the out...

Page 11: ...t corner Repeat with a second piece of short beading and fit into the bottom right corner of the lower groove Place the Window Bar B No 46 onto the Window Bar A No 47 Fit the Window bars into the top and bottom groove by using a circular motion The bar must be central Place the remaining beading No 51 into the grooves and secure using 30mm screws You may want to place a piece of card on top of the...

Reviews: