Meraki MX68CW Installation Manual Download Page 5

All Meraki MX devices must have an IP address. This section describes how to configure your local area 

network before you deploy it. A local management web service, running on the appliance, is accessed 

through a browser running on a client PC. This web service is used for configuring and monitoring basic 

ISP/WAN connectivity.  

 

Setting up a static IP address  

 

To ensure that the client PC is redirected to the local web service in the following step, you must disable 

all other network services (e.g., Wi-Fi) on your client machine. 

Do the following to configure basic connectivity and other networking parameters: 

1.

 

Using a client machine such as a laptop, connect to one of the ten 

LAN

 ports of the MX. 

2.

 

Using a browser on the client machine, access the appliance's built-in web service by browsing 

to 

http://setup.meraki.com

(You do not have to be connected to the Internet to reach this address) 

3.

 

Click 

Uplink configuration

 under the 

Local status 

tab. 

4.

 

Choose 

Static 

for the 

IP Assignment option

5.

 

Enter the IP address, subnet mask, default gateway IP and DNS server information. 

Setting up a DHCP IP address 

By default all MX devices are configured to DHCP from upstream WAN / ISP servers. Simply plug one of 

the MX's WAN / Internet ports into your upstream circuit and wait a few minutes for the unit to negotiate 

a DHCP address. 

Icon 

When the WAN connection is fully enabled, the Internet 1 or 2 LED 1 will turn green. 

Additional settings 

Please note that all these settings below are accessible only via the local management console. 

 

Setting VLANs

 

If your WAN uplink is on a trunk port, choose 

VLAN tagging > Use VLAN tagging

 and enter the 

appropriate value for 

VLAN ID

 for your network. 

Setting PPPoE 

PPPoE authentication may be required if you are connecting the MX to a DSL circuit. You need to know 

your authentication option and credentials (supplied by your ISP) in order to complete these steps. 

 

Choose 

Connection Type > PPPoE. 

 

 

Select your 

Authentication 

option. 

 

If you select 

Use authentication

, enter appropriate values for 

Username

 and 

Password

.  

Summary of Contents for MX68CW

Page 1: ...k administrators who demand both ease of deployment and a state of the art feature set This appliance provides the following new features 2 4 Ghz 2 spatial streams and 5 GHz 2 spatial streams radios f...

Page 2: ...Ethernet LAN WAN SIM K Lock Power Antennas The MX68CW front panel Ports and Status Indicators The MX68CW uses a single LED to inform the user of the device s status Function LED Status Meaning Power U...

Page 3: ...EDs one for activity another for connectivity A steady green LED indicates bidirectional connectivity while a flashing green LED indicates traffic Internet ports Two ports provide connectivity to the...

Page 4: ...w you to mount the appliance on a drywall surface either vertically or horizontally The distance between the holes you drill should be 165 mm For mounting on drywall use a in drill bit then insert the...

Page 5: ...under the Local status tab 4 Choose Static for the IP Assignment option 5 Enter the IP address subnet mask default gateway IP and DNS server information Setting up a DHCP IP address By default all MX...

Page 6: ...This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Party issuing Supplier s Declaration of...

Page 7: ...ncy range then it is restricted to indoor environment only This device meets all other requirements specified in Part 15E Section 15 407 of the FCC Rules Industry Canada Statement This MX68CW complies...

Page 8: ...MHz et 5 650 5 850 MHz et que ces radars pourraient causer du brouillage et ou des dommages aux dispositifs LAN EL Industry Canada Radiation Exposure Statement This equipment complies with IC radiati...

Page 9: ...Taiwan NCC Statement 12 14 4 7 4 7 6 4 7 7 5 25 5 35 MPE 1mW cm2 20cm Statement CS 0438 RoHS RoHS www cisco com go taiwanrohs...

Reviews: