Menvier Security DC58 Installation & Programming Instructions Download Page 4

Connection To Telephone Network

The person responsible for connection of the
DC58/58M to a PABX system is as follows:

l

If the wiring is owned by British Telecom PLC -

British Telecom

l

If the wiring is not owned by British Telecom,

either:

(a)

British Telecom

(b)

The authorised maintainer

(c)

A professional installer after 14 days written

notice to the authorised maintainer.

Overview

General

The DC58/58M digital communicator consists of a
single PCB fitted in a small polycarbonate case. It
is used to transfer fast format status information
from an alarm system to a dedicated Alarm
Receiving Centre (ARC) via the Public Switched
Telephone Network (PSTN). The DC58M offers the
same features as the DC58 but it also functions as
a V21 modem. The DC58M is required when using
the up/downloading feature on compatible

Menvier control panels.

Operating Modes

The DC58 can be used as a stand-alone
communicator, in this mode the communicator is
hard-wired to the control panel using the
appropriate terminal block connections.
Alternatively the unit can be plugged on to a
suitable Menvier control panel, such as the TS510,
TS700, TS790, TS900, TS2500 or TS2200. When used
in this mode the communicator plugs on to the
control panel using the lead supplied. The DC58M
can only be used in the plug-on mode.

4

Overview

DC58/58M Installation Instructions

Plug-on Mode

Stand-alone Mode

(DC58 Only)

Terminal

connections for

other control

panels

TS900 Remote Keypad

(Programmer)

TS900 Remote Keypad

(Programmer)

Plug-on to

Menvier control

panels

Figure 1

Operating Modes

Summary of Contents for DC58

Page 1: ...DC58 DC58M 8 Channel Digital Communicator Digi Modem Installation Programming Instructions...

Page 2: ...y 6 Installation Plug on Installation 8 Stand alone Installation DC58 Only 8 Telephone Line Connections 8 TS900 Remote Keypad Connections 9 Testing 9 Programming Programming Menu 10 Telephone Numbers...

Page 3: ...abel for the DC58M Connections Connection terminals on the DC58 58M are described as either Safety Extra Low Voltage circuits SELV or Telecommunications Network Voltage circuits TNV The PCB layouts on...

Page 4: ...same features as the DC58 but it also functions as a V21 modem The DC58M is required when using the up downloading feature on compatible Menvier control panels Operating Modes The DC58 can be used as...

Page 5: ...ephone fax etc the total voltage drop 40mA MUST NOT exceed 2 0V Operation General When triggered the DC58 58M seizes the PSTN line When a dial tone is detected it tests the line to determine if Loop D...

Page 6: ...tem is not compromised Temporary Out of Service In addition to the line fault monitor the DC58 58M can be programmed to perform a more detailed line test at pre set intervals The DC58 58M will seize t...

Page 7: ...active Flashes on and off 4 times when successfully communicated with the ARC Flashes continuously when modem is in operation 7 Test Call Short these two pins to initiate a test call 8 NVM Removable N...

Page 8: ...or battery supply is still present 3 Remove the cover from the DC58 case and if appropriate fit a pre programmed NVM 4 Connect the input channels to the appropriate outputs on the control panel feedin...

Page 9: ...link it to 12V if the trigger is set to ve or to 0V if the trigger is set to ve 3 Connect power to the control panel If the DC58 is being used as a stand alone wait for approximately 10 seconds for th...

Page 10: ...en Close channels by pressing 1 8 ENT ENT Select Restore channels by pressing 1 8 ENT Consecutive Alternative All 1 2 3 Will NOT Report Limited Report Full Report 1 2 3 Select dialling mode Select poi...

Page 11: ...ing telephone numbers it is very important check that they have been entered correctly otherwise the DC58 58M could dial a private number inadvertently Account Numbers This is a 4 digit number that th...

Page 12: ...sful communication from all alarm receivers Test Call Period The DC58 58M can be programmed to periodically send a Test signal Code 9 to the Alarm Receiving Centre Digicom Outputs The DC58 58M has two...

Page 13: ...ents relating to PA and Intruder activations 3 Full Report When Full Report is selected the DC58 58M will report all extended format data to the alarm receiver irrespective of the channels that are pr...

Page 14: ...L pins are momentarily shorted the DC58 58M will send a test call to all programmed telephone numbers The display should show Other Monitor Messages The following monitor messages may also be displaye...

Page 15: ...nels Invert Channels Dialling Mode Consecutive o Alternative o All o Test Call Period Disabled o Daily o Weekly o Fortnightly o Output 1 ve Line Fault o Digi Success o Digi Failed o Digi Active o Seri...

Page 16: ...18307 Drg No 33 1639 00 Issue 05 Doc 01 March 1997 MENVIER SECURITY Menvier Security Ltd Kenn Road Clevedon Bristol BS21 6LH Tel 01275 870078 Fax 01275 343453...

Reviews: