Regulatory Requirements

General

The DC58/58M digital communicator/modem
must be installed by an electrically competent
person. Before attempting to install the
DC58/58M, the installer must be aware of the
following:

Application

The DC58/58M digital communicator/modem is
suitable for connection to the following types of
telephone line:

l

Direct exchange lines (PSTN) supporting DTMF

(Tone dialling) or Loop Disconnect (Pulse

Dialling).

l

PABX exchanges (with or without secondary

proceed indication).

Approval

The DC58/58M digital communicator/modem is
not suitable for connection as an extension to a
pay phone or 1+1 carrier systems. The DC58/58M
digital communicator/modem is approved for the
following usage:

l

Automatic call initialisation

l

Operation in absence of proceed indication

l

Automatic dialling

l

Multiple repeat attempts

l

Serial connection

l

Three-way calling using BT Network Services

l

Modem

Usage other than the approved usage or failure to
comply with the installation and programming
instructions may invalidate any approval given to
the apparatus. The approval Label for the DC58:

The approval Label for the DC58M:

Connections

Connection terminals on the DC58/58M are
described as either

"Safety Extra-Low Voltage"

circuits (SELV) or

"Telecommunications Network

Voltage"

circuits (TNV).

The PCB layouts on page 7 shows the two types of
circuits.

+

It is important that the installer ensures that

TNV connections are only connected to

the PSTN and SELV circuits are only

connected to other circuits designated as

SELV circuits.

+

Interconnection circuits should be such

that the equipment continues to comply

with the requirements of 4.2 of EN 41003

for TNV circuits and 2.3 of EN 60950 for

SELV circuits, after making connections

between circuits.

Mounting The DC58/58M

The DC58/58M is supplied inside a polycarbonate
enclosure and is small enough to be mounted
inside most control panels.

+

Once the unit is installed the cover must be

secured using the screws supplied.

Compatibility with PABXs

The DC58/58M is only approved for use with
compatible PABX systems. Correct operation in all
circumstances is not guaranteed. If you

experience any difficulties contact Menvier
Technical Support.

3

DC58/58M Installation Instructions

Regulatory Requirements

MENVIER SECURITY

DC58

POWER REQUIREMENTS 12v DC @100mA MAX

R

E

N

=

0

.0

S/1100/3/R/503310

MENVIER SECURITY

DC58M

POWER REQUIREMENTS 12v DC @100mA MAX

R

E

N

=

0

.0

S/1100/3/R/503311

Summary of Contents for DC58

Page 1: ...DC58 DC58M 8 Channel Digital Communicator Digi Modem Installation Programming Instructions...

Page 2: ...y 6 Installation Plug on Installation 8 Stand alone Installation DC58 Only 8 Telephone Line Connections 8 TS900 Remote Keypad Connections 9 Testing 9 Programming Programming Menu 10 Telephone Numbers...

Page 3: ...abel for the DC58M Connections Connection terminals on the DC58 58M are described as either Safety Extra Low Voltage circuits SELV or Telecommunications Network Voltage circuits TNV The PCB layouts on...

Page 4: ...same features as the DC58 but it also functions as a V21 modem The DC58M is required when using the up downloading feature on compatible Menvier control panels Operating Modes The DC58 can be used as...

Page 5: ...ephone fax etc the total voltage drop 40mA MUST NOT exceed 2 0V Operation General When triggered the DC58 58M seizes the PSTN line When a dial tone is detected it tests the line to determine if Loop D...

Page 6: ...tem is not compromised Temporary Out of Service In addition to the line fault monitor the DC58 58M can be programmed to perform a more detailed line test at pre set intervals The DC58 58M will seize t...

Page 7: ...active Flashes on and off 4 times when successfully communicated with the ARC Flashes continuously when modem is in operation 7 Test Call Short these two pins to initiate a test call 8 NVM Removable N...

Page 8: ...or battery supply is still present 3 Remove the cover from the DC58 case and if appropriate fit a pre programmed NVM 4 Connect the input channels to the appropriate outputs on the control panel feedin...

Page 9: ...link it to 12V if the trigger is set to ve or to 0V if the trigger is set to ve 3 Connect power to the control panel If the DC58 is being used as a stand alone wait for approximately 10 seconds for th...

Page 10: ...en Close channels by pressing 1 8 ENT ENT Select Restore channels by pressing 1 8 ENT Consecutive Alternative All 1 2 3 Will NOT Report Limited Report Full Report 1 2 3 Select dialling mode Select poi...

Page 11: ...ing telephone numbers it is very important check that they have been entered correctly otherwise the DC58 58M could dial a private number inadvertently Account Numbers This is a 4 digit number that th...

Page 12: ...sful communication from all alarm receivers Test Call Period The DC58 58M can be programmed to periodically send a Test signal Code 9 to the Alarm Receiving Centre Digicom Outputs The DC58 58M has two...

Page 13: ...ents relating to PA and Intruder activations 3 Full Report When Full Report is selected the DC58 58M will report all extended format data to the alarm receiver irrespective of the channels that are pr...

Page 14: ...L pins are momentarily shorted the DC58 58M will send a test call to all programmed telephone numbers The display should show Other Monitor Messages The following monitor messages may also be displaye...

Page 15: ...nels Invert Channels Dialling Mode Consecutive o Alternative o All o Test Call Period Disabled o Daily o Weekly o Fortnightly o Output 1 ve Line Fault o Digi Success o Digi Failed o Digi Active o Seri...

Page 16: ...18307 Drg No 33 1639 00 Issue 05 Doc 01 March 1997 MENVIER SECURITY Menvier Security Ltd Kenn Road Clevedon Bristol BS21 6LH Tel 01275 870078 Fax 01275 343453...

Reviews: