27
1.
Remove the regulator cap with a adjustable open end or channel lock pliars (turn counter-clockwise), and
observe the removable plastic stem:
2. Snap out the plastic stem and rotate it to the LP Position:
3. Reinstall regulator cap and stem:
Natural Gas Position
- as shipped.
Natural Gas
Position
LP
Position
LP Position
- as modified