SPECIFICATIONS
MODEL DXV-35 TIMBER FIRE
High Fire - Adjustable to - Low Fire
BTUH. (MODEL DXV-35)
NAT. GAS
33,000
21,000
BTUH. (MODEL DXV-35)
LP GAS
33,000
18,500
MAIN ORIFICE………………………#32 NAT. GAS -- #50 L.P. GAS
OVERALL EFFICIENCY
....................
EXCEEDS D.O.E. EFFICIENCY REQUIREMENTS (A.F.U.E.) FOR DIRECT VENT
............................................................... WALL HEATERS
CO-AXIAL DIRECT VENT FLUE ..... TOP VENT:
4" INNER, 6 5/8" OUTER;
REAR:
5” INNER 8” OUTER
TOTAL WEIGHT ................................. 185 POUNDS
SAFETY ................................................ AGA CERTIFIED PILOT GENERATOR, MILLIVOLT SYSTEM
ACTIVATED WITH SWITCH, THERMOSTAT OR REMOTE CONTROL.
GAS REQUIREMENTS ........................ SUPPLY PRESSURE:
GAS INLET: 3/8" N.P.T.
NAT.
GAS:
7" W.C.
(5" W.C. MIN., 11" W.C. MAX.)
L.P.
GAS:
11.0" W.C.
(11" W.C. MIN., 13" W.C. MAX.)
ELECTRICAL REQUIREMENTS ....... 115 VOLT, LESS THAN 2 amps
APPROVED VENT SYSTEMS: AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to floor
0 in.
Unit to enclosure sidewalls
0.5 in.
Unit to enclosure sidewall
0.5 in.
Unit top to ceiling
18 in.
Vent to enclosed
1 in.
Wall Pass-Through to framing
1 in.
Vent to adjacent sidewall
10 in.
Mantle above discharge air opening 14 in.
Certified under ANSI Z21.88 (2002) CSA 2-33 (2002) “Vented Gas Fireplace Heaters" not for use with solid fuel. Approved
for bedroom installations and mobile homes. UL307B approved for "mobile homes, after first sale of home, not for recrea-
tional vehicles."
Gas appliances must be tested and certified by a nationally recognized testing and certification agency to American National
Standards Institute - ANSI Gas Appliance Safety Standards
The Mendota Gas DXV Fireplace has been tested and certified by Intertek Testing Services 8431 Murphy Drive, Middleton, WI
FIREPLACE INCLUDES A HEARTHGLO SEALED COMBUSTION SYSTEM, 6-PIECE CERAMIC FIBER LOG SET &
COALS, FIREBRICK LINED FIREBOX, NEO-CERAM GLASS, PIEZO IGNITER, DUAL BLOWERS, AGA CERTIFIED
SAFETY SYSTEM, and WALL THERMOSTAT.
OPTIONS: DIRECT REAR VENT KITS, BLACK, BRASS, CLASSIC BRASS OR CLASSIC SILVER TONE GRILL SETS,
BLACK OR 24K GOLD "VICTORIA" & “TUSCANY” FILIGREE FRONTS, ANDOVER ARCHED DOORS & 4 COLOR
OVERLAY FRONTS, PRAIRIE RECTANGULAR DOORS & 4 COLOR OVERLAY FRONTS, WELLINGTON FRONT,
VERSIHEAT REMOTE FORCED AIR HEAT- TRANSFER SYSTEM, LP CONVERSION KIT.
Building Permit and Installation Inspection Approval Requirements
All installations of Mendota Fireplaces and Inserts must comply with all the re-
quirements stated in this Installation and Operating Instructions Manual. The
Dealer and/or installer must also obtain all required Building Permits and Inspec-
tion Approval from the local building inspection department or the local body
having jurisdiction. In order to validate warranty coverage, Mendota may re-
quire facsimile copies of the Building Permit and Inspection Approval forms.
Failure to provide adequate proof that the installation conforms to all local re-
quirements and the requirements stated in the Installation and Operating Instruc-
tions Manual will void all applicable warranty.
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER.