85-03-01154
FV36 DÉCOR
Page
36
-
On fireplaces with electronic ignition system that come with a PF2 remote the convection fans function must be
programed out of the remote. This will ensure that the convection fans cannot be turned on. Follow the directions below
to remove the convection fans function from the remote.
1.
Remove a battery from the remote.
2.
Hold down both the ON/OFF key and MODE key
and reinstall the battery.
3.
Continue to hold the ON/OFF key. Release the
MODE key. Press the MODE key once to highlight
the convection fan
function.
4.
While still holding the ON/OFF key press the DOWN
ARROW key. The display will change from “Set” to
“Clr” to indicate that the convect
ion fan function
has been disabled.
5.
Release the ON/OFF key.
3.2.17.3.1
Mendota Cool Wall
The Mendota Cool Wall system uses natural convection to take heat off the wall directly above the fireplace and redirects it up and
away from surrounding areas. Testing has shown that when using a Cool Wall system, temperatures above the fireplace are
reduced making it possible to mount a television 15” above the fireplace’s top air gap.
Summary of Contents for AA-11-04109
Page 2: ...85 03 01154 FV36 D COR...
Page 16: ...85 03 01154 FV36 D COR Page 16 Figure 3 11 Figure 3 10...
Page 87: ...85 03 01154 FV36 D COR Page 87 Gas Train Assembly Parts Figure 5 5 Gas Train Assembly Parts...
Page 88: ...85 03 01154 FV36 D COR Page 88 Burner Figure 5 6 Burner...
Page 95: ......