background image

10

COMBUSTION AIR & PERMANENT AIR VENT

In order for the stove to perform efficiently and safely there should be an adequate permanent air supply
into the room in which the stove is installed to provide combus�on air. This is par�cularly necessary if the
room is double-glazed or a flue draught stabiliser is opera�ng in the same room as the appliance. The
provision of air supply to the stove must be in accordance with current Building Regula�ons Approved
Document J. An opening window is not appropriate for this purpose. Air inlets must be posi�oned in such
a way that they cannot be blocked. An air inlet may be a vent (the vent must be open and the capacity for
the vent sufficient when the stove is lit).

Ashco� Wide models take all combus�on air (primary, secondary & ter�ary) from a single 80mm port at
the bo�om rear of the stove, with the door closed the air port supplies all combus�on air for the
appliance. This port can be connected to the outside via a 80mm pipe so the appliance does not draw
combus�on air from the room. However as this stove needs the door to be ajar when ligh�ng and
combus�on air is taken from the room when reloading. Mendip stoves recommends the use of an
addi�onal air vent as laid out in Document J .

The stove requires a permanent air vent to the room . This is to provide adequate air supply in order

for the stove to operate safely and efficiently. In accordance with current Building Regula�ons the

installer may have fi�ed a permanent air supply vent into the room in which the stove is installed to

provide combus�on air. This air vent should not under any circumstances be shut off or sealed.

SE Cleanheat- Smoke Exemp�on Modifica�on

Smoke exempt (SE) models are factory fi�ed with an air stop on the air control slider: To adjust the smoke
control se�ngs, use an Allen key to adjust the fixing in the air intake (at the rear of the stove).

The air control on the Ashco� Wide 5kW SE Model has 40mm movement.

The SE fixing is designed to prevent the air supply of the stove from being completely shut off; this
promotes complete combus�on and therefore acts to decrease harmful pollutants as a result of
incomplete combus�on

.

DO NOT OBSTRUCT THE AIR INTAKE

At least 40mm clearance should be le� between the air intake and the wall

COMBUSTION CHAMBERS

Mendip Stoves are fi�ed internally with vermiculite heat deflec�on panels and baffles, these are designed
to ensure the maximum efficiency and are an integral part of the clean burn process of the stove. These
baffles should not be removed other than for cleaning the stove. Any defec�ve panels should be replaced,
small hairline cracks do not need replacement, however small cracks can develop during use to a larger
crack, if this passes through the vermiculite to the stove body then the panel must be replaced. When
refuelling your stove place the wood fuel into the chamber (wearing a glove), impact from logs can cause
the heat deflec�on panels to crack

.

.

Summary of Contents for Ashcott with logstore

Page 1: ...OPERATION AND INSTALLATION MANUAL Guide d u lisa on et Mode d Emploi WOODBURNING SMOKE EXEMPTION MODELS ASHCOTT WIDE ASHCOTT WIDE PEDESTAL...

Page 2: ...conv panel Profondeur inc la poign e C3 348 mm 348 mm FLUE OUTLET DIAMETER Diam tre du conduit de fum e D 125 mm 125 mm CENTRE OF FLUE TO REAR OF STOVE Centre de la sor e de fum e et l arri re du po...

Page 3: ...d proof of purchase supplied Full terms and condi ons are detailed in the Warranty Statement on the Eurostove website www eurostove co uk In the event of any conflict of informa on the wording on the...

Page 4: ...xide alarm must be fi ed in the same room as the appliance Further guidance on the installa on of the carbon monoxide alarm is available in BS EN 50292 2002 and from the alarm manufacturer s instruc o...

Page 5: ...by unbol ng from the body of the stove 2 Break off tabs on rear convec on panel and remove the laser cut sec on To do this the rear convec on panel does not need to be removed 3 Remove rear cover pla...

Page 6: ...exempt models with a 125mm collar burning wood only can be installed on a flue of 125mm throughout Any bend in the chimney or connec ng flue pipe should not exceed 45 90 bends should not be used other...

Page 7: ...ng Notes 1 The weather surface is the building external surface such as its roof les or external walls 2 A flat roof has a pitch less than 10 3 The clearances given for A or B as appropriate will also...

Page 8: ...lls of fireplaces or flues could ignite it Therefore when installing the stove in the presence of combus ble materials due account must be taken of the guidance on the separa on of combus ble material...

Page 9: ...ficient air flow available to it during opera on please allow at least 40mm of clearance from the back of the air intake to the rear wall This means that if you are installing your stove between 50mm...

Page 10: ...d efficiently In accordance with current Building Regula ons the installer may have fi ed a permanent air supply vent into the room in which the stove is installed to provide combus on air This air ve...

Page 11: ...as this can cause excessive heat and damage the stove see table on page 8 ALWAYS KEEP FUEL LOAD BELOW TERTIARY PORTS AT REAR OF STOVE Only use fuels approved for use on hea ng stoves Do not burn liqui...

Page 12: ...ates by moving from le to right Catalyser by pass control The catalyser by pass control is on the rear of the stove This operates by being pulled out and pushed in to open and close a vent in the cata...

Page 13: ...10 min s The door can now be closed remove door spacer tool and push door closed un l magne c closure has located Leave the air control in the far le posi on If the stove flames begin to falter and ge...

Page 14: ...ence to acquire an unauthorised fuel for use within a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area In England...

Page 15: ...n occur Refuelling must be carried out onto a sufficient quan ty of glowing embers and ash that the new fuel charge will ignite in a reasonable period If there are too few embers in the fire bed add s...

Page 16: ...e stove requires a permanent air vent to the room This is to provide adequate air supply in order for the stove to operate safely and efficiently In accordance with current Building Regula ons the ins...

Page 17: ...t forms on the window a The firewood may be too wet b the intake of secondary air may be insufficient c fire not hot enough 4 The stove fails to heat fully a The firewood may be too wet b the intake o...

Page 18: ...ned fuel residues To enable a good flow of air through the appliance to reduce condensa on and subsequent damage leave the air controls fully open It is important that the flue connection any applianc...

Page 19: ...ter pour www eurostove co uk derni res informa ons pi ce de rechange LOOSE PARTS PI CES D TACH ES Always use the opera ng tools provided when handling parts likely to be hot when the stove is in use Y...

Page 20: ...e the two base bricks 2 li up the front edge and slide forward Re rez les deux briques de base 2 soulevez le bord avant et faites les glisser vers l avant Remove rear brick 3 by sliding forward bo om...

Page 21: ...accumulate on the surfaces in normal use Ashes accumulate both as a result of the smoke being burned within the catalyser and by being carried out of the firebox by the chimney dra Soot is o en the re...

Page 22: ...0 00 COMPLETE DOOR SEAL Jointe de porte 1 6 M10570 01 02 00 00 GLASS SEAL Jointe de vitre 1 7 M10560 01 13 99 00 GLASS CLAMP Serre de vitre 6 8 U91002 00 00 31 00 M6 WASHER M6 rondelle 6 9 U91000 98 0...

Page 23: ...23...

Page 24: ...stoves co uk E mail info mendipstoves co uk france eurostove co uk www eurostove fr www eurostove co uk Mendip Stoves Ltd 2019 ver 1 Nov 2019 MP ASHCOTT WIDE ENERGY LABEL M10570 49 02 00 00 VERSION 1...

Reviews: