background image

 

Ver 2.7, 2021.8.5 

 

 

 

 

 

 

 

 

MEND Professional

TM

 (IS02PROs) 

User’s Manual 

 

 

Summary of Contents for IS02PROs

Page 1: ...Ver 2 7 2021 8 5 MEND ProfessionalTM IS02PROs User s Manual...

Page 2: ...d trademarks are the property of their respective holders Software and specifications are subject to change without notice Technical Support Website https www mendtechnology com Email support mendtech...

Page 3: ...r Running 15 Install Batteries 15 Connect Wires to the MEND ProfessionalTM device 15 Connect Wires to Gloves Strips or Electrodes 16 3 2 Basic Operations 17 Power ON 17 PROTOCOLS button All Recent His...

Page 4: ...s MAIN MENU 26 To change Settings 26 To turn ON OFF key beeping 26 To turn ON OFF protocol end beeping 27 To change the OUTPUT Drive Voltage 27 About 27 To go to About 27 Version Battery Status Discla...

Page 5: ...ty current pulses at microampere levels and frequency of pulses This unit can hold multiple therapy protocols Each protocol includes multiple frequency pairs Health practitioners can program each freq...

Page 6: ...symptomatic treatment and as such suppresses the sensation of pain which would otherwise serve as a protective mechanism The stimulation and electrodes should not be applied across or through the head...

Page 7: ...burns If gloves or cloth or garment are used as electrodes these gloves or cloth or garment should be wet or damp If electrode pads are used sometimes conductive gel on pads can be helpful to increase...

Page 8: ...mable mixtures or concentrated flammable fumes such as gasoline The device can only be opened and repaired by the manufacturer or licensed service personnel Do not modify the device as it can be unsaf...

Page 9: ...ing the Product The MEND ProfessionalTM unit may be repaired or replaced with the same or a substitute product within one year of purchase based on the determination of the manufacturer Lead wires hav...

Page 10: ...s Indication LED CH1 and CH2 indicate if the output current can reach their peak current value in the protocol for channel 1 and channel 2 respectively If the LED is flashing or ON check the connectio...

Page 11: ...er Press this key again to move to next number or to finish entering numbers Protocols Press this key to cycle between All Protocols Recent Protocols History Protocols and Batch Protocols Back Light t...

Page 12: ...ertified computer has one or more of the following markings on the power supply unit Micro USB connection to PC Combined Channel Jacks Refer to user s manual for safety cautions Positive Jack Positive...

Page 13: ...ellow CH2 Jack Tip CH2 Blue Ring CH2 Green Table 1 Color Mapping of Output Ports to Wire Connectors Plugging into POS and or NEG jacks will not cut off signals on CH1 and CH2 jacks Signals will always...

Page 14: ...14 Combinable Leadwires Carrying Case Sticky pads Conductive Strip Alligator Clips...

Page 15: ...s two alkaline batteries in size AA Remove the batteries when the device is not going to be used for more than one month Connect Wires to the MEND ProfessionalTM device Insert the plugs into the jacks...

Page 16: ...END ProfessionalTM after use If you want to unbutton the electrode wires from the gloves hold the button base on the gloves instead of holding the fiber part of the gloves to avoid damage to the glove...

Page 17: ...y used Use Recent Protocols to quickly select your most frequently used protocols History Protocols lists the actual protocol running history The latest used protocol is displayed on the top of the li...

Page 18: ...in the MEND ProfessionalTM device Select by protocol number from Power On Screen or from All Protocols screen press the protocol number with the numeric keys For example to select protocol number 215...

Page 19: ...rotocol will stop after the programmed run time The CH1 CH2 LEDs will flash to indicate poor connection from the device to the body Pause the Therapy Protocol While a protocol is running press the PAU...

Page 20: ...turn off the back light immediately To turn on the LCD back light for 30 seconds press and hold the back light key for 3 seconds the light will stay on for 30 seconds To keep the backlight on for 8 h...

Page 21: ...ed firmly into the jacks and your pins are plugged into the conductive material The common problems are loose plugs plugs are not inserted the button or push pin is not inserted into gloves or electro...

Page 22: ...sity value Or press SET key until the edit cursor has moved to the output current position then use number keys or arrow keys to change the value To change polarity Press POL key to rotate the output...

Page 23: ...Intensity and Waveform will be carried into next frequency pair in the protocol if the next frequency pair has the same parameters as the current frequency pair All Run Time changes become invalid wh...

Page 24: ...slots Remove a protocol from batch select the batch slot and press and hold STOP key for 2 seconds until the slot is changed to empty You can have empty slots between protocols in the batch The empty...

Page 25: ...run To change CH1 frequency Press CH1 the edit cursor will jump to CH1 frequency value Then enter the digits of the new frequency value For example to enter frequency 970Hz press CH1 9 7 0 0 and SET...

Page 26: ...y to hold the timer the elapsed timer will continue counting the remaining run time timer is on hold Press HOLD again to resume the timer To stop running press STOP key at any time The elapsed time an...

Page 27: ...take effect after you press t h e BACK key to the Main Menu About To go to About press Back key to go to Main Menu and use UP DOWN to select About and press RIGHT arrow to enter into About screen Vers...

Page 28: ...dication Low battery will be indicated on startup screen and on protocol running screen You can continue to use the IS02 but the machine may shut down unexpectedly any time On startup screen On protoc...

Page 29: ...CH1 Use the YELLOW pin to touch the GREEN pin The CH1 LED on the unit should not flash This is the indication of good continuity through the lead wires Separate the touch of the two pins The CH1 LED...

Page 30: ...ice to malfunction To sanitize lead wires wipe the leads with cotton balls or sanitizing wipes with germicide or alcohol To sanitize the electrodes or gloves Electrodes and gloves are single patient u...

Page 31: ...n running a protocol The contact from MEND ProfessionalTM to the skin may be lost This is caused by poor connection or dry skin You need to make the skin moist If CH1 CH2 LEDs continue flashing it mea...

Page 32: ...grammable from 4 ms to 60000 ms Modulation Waveform Programmable ramp up down slopes Programmable duty cycles Current Intensity 20 A to 400 A programmable In 10 A increment Current Accuracy 20 A 200 A...

Page 33: ...nd complexity of the protocols General Power Supply 2x 1 5V Alkaline batteries AA size Battery Life 30 to 70 hours depends on the protocols and backlight usage Power Consumption 0 25 Watts Communicati...

Page 34: ...t 12 000 meters 40 000 feet Atmospheric Pressure 69 kPa 132 kPa 23 kPa 132 kPa Wait for at least 10 minutes before use from the extreme non operating temperature 5 2 Protocols and Frequency pairs MEND...

Page 35: ...ent practitioners or medical doctors usually program the unit with customized protocols for patients according to their therapy needs The following table is an example of a protocol including 10 frequ...

Page 36: ...from 1 minute to 60 minutes for each frequency pair The waveform will be repeated during the therapy time I Peak current intensity of the pulse expressed in A Polarity The polarity of the pulse is pro...

Page 37: ...dulated pulse The pulse can be modulated by the carrier frequency F The period is programmable from 4 ms to 60000 ms The outline of the waveform is often referred to as the envelope of the waveform wh...

Page 38: ...38...

Page 39: ...39...

Page 40: ...logy 10117 SE Sunnyside Rd Suite F40 Clackamas OR 97015 Toll free 855 445 3971 Direct 503 594 4045 Fax 503 594 4046 www MENDTechnology com support mendtechnology com Copyright 2021 MEND Tech LLC All r...