Getting Started
Page 18
2.2.1
Safety Instructions for Mounting
2.2.2
Mounting on a Wall or a Horizontal Surface
The following steps are necessary:
»
Carefully measure and mark the position of the required screw holes to match the
position of the mounting holes on the NL30.
»
Drill the screw holes for the M5 pan-head screws at the marked location.
»
Secure the M5 pan-head screws at the marked location, making sure to leave at
least the following gap between the surface and the screw head:
-
5 mm
»
Place the NL30 so that the wide openings of the mounting holes are over the screw
heads (1).
Risk of Damages or Injuries
Make sure that the cabinet or the wall where you want to install the
system supports the weight of the system.
Risk of Fire Through Overheating
Make sure that the equipment does not overheat. Overheating can cause
fire or malfunction of the device. Conformity to standards expires.
Mount the equipment only in the mounting position described in this
document.
Adhere to the environmental conditions specified in the Technical Data.
Leave enough space to the sides of the system that are needed for
cooling to enable the required airflow as specified in chapter Cooling
Concept.
Do not install the system near any heat sources (e.g., radiators, heaters).
Risk of Damage Through Liquids
Keep the system away from liquids. Avoid exposure to dripping or
splashing.
The necessary length of the M5 screws to mount the NL30 depends
on the structure of the surface.