![MEN G25A User Manual Download Page 35](http://html1.mh-extra.com/html/men/g25a/g25a_user-manual_1770468035.webp)
Functional Description
Page 35
3.3.3.2
Hot-Swap LED
The hot-swap LED signals the hot-swap status.
Table 4.
Hot-swap LED
If the hot-swap switch is closed after system shutdown, the board controller initiates
Power Resume
3.3.3.3
Software Support
Supervision and management functions are accessible by software.
Hot-Swap LED
Description
Off
The hot-swap switch is closed.
Starts flashing
The hot-swap switch is opened while the system is running
(start of hot-swap sequence).
Lights continuously
The system has been shut down (end of hot-swap sequence).
The hot-swap switch is open during power-up. The board
controller delays the power-up sequence until the hot-swap
switch is closed.
Stops flashing
The hot-swap switch has been closed while the hot-swap
sequence is in progress. The board controller no longer waits
for system shutdown.
Inactive
The CPU is plugged into a system slot or is in S0 or S3 state. The
board controller ignores the hot-swap switch.
Please refer to the ACPI Specification for more details on the power states
S0 to S5:
Advanced Configuration and Power Interface Specification Version 6.1
January, 2016
Unified EFI Forum
See
Chapter 2.6.1 Accessing SMBus/I2C Devices on page 24
Accessing Board Management Functions on page 26
for details on using MEN driver
software.
See
Chapter 5.4 BMC API (Application Programming Interface) on page 62
for a
detailed documentation of the BMC API.