CONNECTIONS
CONNECTOR
DESCRIPTION
A
PWR
Power supply connector
B
USB
USB connector for upgrades
C
TEL1/TEL2
RJ11 FXS connectors for communicators
D
Antenna
SMA/f connector for external GSM antenna
E
SIM
SIM connector
F
Switch
Switch for the device power off-on
C
B
D
A
E
F
INSTALLATION
For a correct installation, turn the device off and read the following instructions.
1.
Connect the GSM antenna to the SMA connector being careful not to over-
tighten.
2.
Insert the SIM Card into the SIM holder. Be sure the SIM is inserted in the
correct way being careful of the SIM corner, with the golden contacts are
placed downwards.
3.
Connect the Emergency Telephone to one of the TEL1 / TEL2 connector
present on the back side. The 2 connectors are connected together so there
is no difference between the two ports.
4.
Connect the power supply and turn the GSM Gateway on using the switch.
5.
For use with Memco memcom or C100 emergency telephones, the setings >
System Config > Alt. dial tone option must be ticked in the phone settings.