Keep the areas surrounding the grill free from
combustible materials including, fluids, trash, and
vapors such as gasoline or charcoal lighter fluid. Do
not obstruct the flow of combustion and ventilation air.
WARNING
This outdoor cooking gas appliance is not
intended to be installed in or on boats.
recreational vehicles.
CHECKING FOR GAS LEAKS
Never test for leaks with a flame. Prior to
First use and at the beginning of each new
Season, you must check for gas leaks.
Follow these steps:
1.
Make soap solutions by mixing one part liquid
detergent and one part water.
2.
Turn off heat control valves, and then turn on gas
at source
NATURAL GAS SAFETY
Your natural gas is designed to operate on natural
Gas grill only, at a pressure of 4” water column
(1/4 psig or 1.75kpa) regulated at the pre-set supplied
regulator. Check with your gas utility for local gas
pressure and with your local municipality
for building code requirements. If your residential gas
Utility line pressure has not utility or gas grill dealer
for professional assistance
Total gas consumption (per hour)
Of grill with all burners on “IGNITE/HI”
Main burner
55,500 Btu/Hr
Sear burner
15,000 Btu/Hr
Rear burner 10,000 Btu/Hr
Total
80,500 Btu/Hr
Check with your gas utility or with local building codes
For instructions to install gas supply line, or call a licensed
And knowledgeable installer.
It is recommended that an “ ON-OFF” shut off valve be
Installed at the gas supply source;
Outdoor after the gas line piping exits outside the wall and
Before the quick-disconnect. In a branch fuel line, it should
Installed before the
Apply the soap solution to all gas connections. Bubbles
Will appear in the soap solutions if connections are not
Properly sealed. Tighten or repair as necessary
If you have a gas leak that you cannot repair, turn off the
Gas at the source, disconnect the fuel line from grill and
Immediately call your grill dealer or gas supplier for
Professional assistance, gas line piping enters the ground
Indoors in an accessible location near the supply
Pipe sealing compound or pipe thread tape of the type
Resistant to the action of natural gas must be used on all
Male pipe threads when marking the connection
Disconnect your gas grill from its fuel source when the
Gas company is testing the gas supply lines at high
Pressure. This appliance and its individual shut off valve
Must be disconnected from the gas supply piping system
During any pressure testing of that system at pressure in
Excess of ½ psi (3.5kpa)
Turn OFF your gas grill when the gas company is testing
The gas supply at low pressures. This appliances must be
Isolated from the gas supply piping system by closing its
Individual manual shut OFF valve during any pressure
Testing of the gas supply piping system at pressures equal
Or less than ½ psi (3.5kpa)