MEM (Shenyang Shicheng Printing Machinery Co., Ltd.) |
| +86 13889380068
Operation
Pneumatic connection
TQ-4050 requires air compressor with minimum 800w (1 hp) and 30L (8 gallon) hold tank.
Connect 5mm inner diameter (usually 8mm outer diameter) air hose to the machine.
Charge the compressor to 0.6-0.7 Mpa, up to 0.8 Mpa (120 psi) if possible.
Set the desired pneumatic pressure on the air reducing valve of the heat press by pulling up
the cap at the top end and then turning it. After the pressure is set, push the cap back down.
The set pressure should be lower than on the manometer of the compressor. Commonly used
pressures are between 0.4 to 0.6 Mpa (60 to 90 psi).
Power supply
Connect the heat press to a power socket using the connection cable supplied.
Switch on the press with the red power switch.
Operating transfers
Set the desired pneumatic pressure on the air reducing valve of the heat press by pulling up
the cap at the top end and then turning it. After the pressure is set, push the cap back down.
Bring the press head into an end position right or left.
Manual mode: Shuttle the upper platen over the garment and design. Press both Press
Buttons located on the side of the head to press.
Semi-auto mode: The heat plate will press automatically when the head reaches either end.
After the timer count to zero, the heat plate lifts automatically.
By pressing the red emergency stop button, transfer process can be stopped at any time.
Operation of solenoid valve