MEM (Shenyang Shicheng Printing Machinery Co., Ltd.) |
| +86 13889380068
Controller
With the temperature controller, temperature (°C and °F) and pressing time can be adjusted. The Set
Value are showing the setting value, the Temperature digits are showing the actual value. Counter
(reset after power off) function that counts the number of transfers that have already been made
during the current session could be enabled, contact MEM for counter function enable instruction.
Press and hold SET button to enter parameter setting interface, press and hold SET
button to exit parameter setting interface.
Press down key to decrease the corresponding parameter value.
Press up key to increase the corresponding parameter value.
Press and hold up key to start self-tuning (℃ or ℉on the panel blinks.) Once the
machine begins self-tuning, do not unplug or press any key until the self-tuning is
done (℃ or ℉ stop blinking). Before apply self-tuning, set temperature to normal
working temperature and let the heat plate cool down to room temperature. Apply
self-tuning when the machine could not control temperature properly. Self-tuning will
change PID parameter automatically.
Do not change parameters except Pb and SL2 without our instruction.
Parameter code
Function
Pb
Temperature calibration: If measured temperature 1℃ or 1℉ lower than the
showing temperature, decrease the value 1.
SL2
0: Celsius (℃)
1: Fahrenheit (℉)