Ventilation with heat recovery 

M-WRG-S is a decentralized ventilation system with 
heat  recovery  from  Meltem.  It  adds  to  the  value  of 
your  home  and  creates  a  healthier  indoor  climate, 
and  is  a  protective  measure  against  moisture  and 
mold damages in your home. 
Ventilation  by  opening  windows  especially  during 
cold  seasons,  belong  to  the  past.  From  now  on, 
fresh  and  filtered  air  is  supplied  fully  automated. 
The stale air is extracted from your home and while 
passing  through  the  heat  exchanger  its  warmth  is 
transferred  to  the  fresh  air.  While  doing  so,  the  M-
WRG-S  ventilation  units  have  minimum  power 
consumption. You save heating costs, increase the 
comfort of your home and at the same time reduce 
the  impact  on  the  environment  by  reducing  CO2 
emissions. 
Of  course  you  still  may  open  your  windows  - 
especially during warmer days. 
 
A family of four produces daily an average of 10-14 
litres of moisture, due to cooking, laundry, personal 
hygiene,  and  breathing  of  inhabitants,  plants  and 
animals! This excessive  amount of moisture,  within 
the  interior  air,  is  extracted  through  the  M-WRG 
ventilation  unit  and  therefore  prevents  the  forming 
of  mold  and  resulting  building  damages.  At  the 
same  time,  fumes  from  floors,  furniture  and  a  too 
high CO2 concentration in the air, which can lead to 
fatigue and health issues, will be extracted from the 
interior rooms and replaced by fresh and clean air.  

 

Directions for correct usage  

 
Please  read  this  manual  carefully  and  follow  the 
instructions  contained  in  this  manual.  Familiarize 
yourself with the M-WRG-S ventilation unit, and pay 
attention to the warnings and cautions contained in 
this manual. 

 

  Never  operate  the  M-WRG-S  ventilation  unit 

without  filters.  Only  with  the  original  filters  from 
Meltem,  the  units  will  remain  clean,  fully 
operative, and have a long lifespan. 

 

  The  M-WRG-S  ventilation  unit  may  only  be 

operated once installed correctly. 

 

  When  ventilating  basements  or  similar  rooms  we 

advise  to  be  cautious  (especially  during  the 
summer  season  and  warm  weather),  due  to  the 
fact  that  the  moisture  in  the  air  will  condense  on 
cold  interior  walls  and  -  despite  ventilation  – 
moisture  damages  can  occur.  Therefore  only 
ventilate at night during warm weather seasons! If 
you  would  like  to  ventilate  such  rooms  with  a  M-
WRG  ventilation  system,  please  consult  with  the 
manufacturer prior to purchase. 

 
 

 
 
 

  Never cover the M-WRG-S ventilation unit or any 

part  of  it  with  e.g.  cabinets,  blinds  or  curtains.  A 
minimum  distance  of  30  cm  to  any  furniture  is 
required,  in  order  for  the  M-WRG-S  ventilation 
unit to remain fully operable. 

 

   The  M-WRG-S  ventilation  unit  has  been 

designed  for  continuous  operation  and  a  long 
lifespan.  During  cold  seasons,  the  M-WRG-S 
ventilation  unit  should  be  operated  continuously. 
High 

efficient  DC  motors  and  innovative 

electronics ensure a very low power consumption 
of  approx.  3.8  Watt  at  ventilation  rate  I.  Only  a 
continuous  operation  achieves  a  permanent 
extraction  of  moisture  and  condensation.  If  this 
does not occur, it is possible that condensate will 
gather in the unit. 

 

  If  a  high  concentration  of  moisture  occurs,  we 

recommend  to  regularly  ventilating  the  room  at 
the  highest  ventilation  level  for  10  minutes,  in 
order  to  eliminate  any  possible  condensation 
inside the unit. 

 

  In  order  to  guarantee  a  smooth  operation, 

especially  during  low  exterior  temperatures 
(below 

-5°C), 

you 

should 

avoid 

interior 

temperatures below 15°C. 

 

Caution: In case of exterior temperatures below 
0°C,  icicles  may  form  at  the  façade  covers. 
These should be removed for safety purposes. 
 
 

Filter replacement 

 

The  ventilation  unit  automatically  monitors  the  filter 
status.  An  acoustic  warning  signal  will  inform  you, 
when the filters need to be replaced. 
  
However,  for  hygienic  reasons,  it  is  strongly 
recommended to replace the filters at least once 
per year
, ideally before the heating season. 

 

For a reliable operation of the units and for your 
own  safety,  only  original  and  certified  parts 
from  Meltem  shall  be  used.  Otherwise  this  may 
void  the  warranty  and  Meltem  will  not  be  liable 
for any damages. 
 
 
 
We  hope  you  will  enjoy  your  new  M-WRG  home 
ventilation system with heat recovery! 

 

Summary of Contents for M-WRG-S

Page 1: ...Best Nr 5302 00 01 03 2011 USER MANUAL HOME VENTILATION WITH HEAT RECOVERY Ventilation Unit M WRG S ...

Page 2: ...we advise to be cautious especially during the summer season and warm weather due to the fact that the moisture in the air will condense on cold interior walls and despite ventilation moisture damages can occur Therefore only ventilate at night during warm weather seasons If you would like to ventilate such rooms with a M WRG ventilation system please consult with the manufacturer prior to purchas...

Page 3: ... S ventilation unit overview 6 2 Start up and Operation 7 3 Filter Replacement 8 3 1 Filter selection 8 3 2 Replacement of Filters 8 3 2 1 Remove unit cover 8 3 2 2 Remove old Filters 9 3 2 3 Insert new Filters 9 3 2 4 Put back on cover 10 4 Cleaning the M WRG S ventilation unit 10 5 Trouble shooting 11 6 Antifreeze Protection 11 7 Technical Data 12 ...

Page 4: ...in It is not suitable for drying a building during construction or to ventilate a building while interior renovations are in progress A continuously high concentration of dust and or moisture will clog the filters additionally and overwork the automated extraction of condensate Never operate the M WRG S ventilation unit without the suitable filters The filters protect your health and your living s...

Page 5: ...fresh air from the exterior As the air streams move through the air ducts of the heat exchanger core heat is transferred from the warm passage to the cold while the airstreams are never combined The cooled stale air is led out and the pre tempered fresh air then streams into the room without causing a draft Interior Stale Air Intake Supply Air Outlet Exterior Fresh Air Intake Exhaust Air Outlet St...

Page 6: ... overview Casing Cover Dual switch Power switch ON OFF 3 level switch for Ventilation Rate Supply Air Outlet Stale Air Intake Ring Cover for Stale Air Filter Cover for Supply Air Filter Facade Cover Ventilation Hood Fresh Air Intake Exhaust Air Outlet ...

Page 7: ... time to ventilation level III During the winter season it is recommended to ventilate the room once daily for 10 minutes at the highest ventilation rate III in order to avoid any condensate buildup inside the M WRG S ventilation unit Caution Before turning off the M WRG S ventilation unit while exterior temperatures are below 0 C the unit has to be run for a minimum of 10 minutes at level III for...

Page 8: ...e Activated Carbon Filter F6 only needed for supply air Only use original filters from Meltem Otherwise Meltem cannot guarantee a smooth operation and may not be held liable for any malfunctions Replacement filters can be ordered at your local HVAC supplier or at www meltem com 3 2 Replacement of Filters No tools are required for filter replacement Both filters should be replaced at the same time ...

Page 9: ...r covers making sure the marked arrows on case and cover are aligned and turn right The marking arrow on the cap has to align with the marking on the M WRG S ventilation unit Make sure the covers sit flat and tight on the cover Repeat this process for both supply and stale air filter caps Note Allergy Filter or Activated Carbon Filter need to be installed for the supply air only on the right side ...

Page 10: ...l the hooks on each side snap into place Turn the M WRG S ventilation unit back on with the power switch 4 Cleaning the M WRG S ventilation unit The M WRG S ventilation unit is made of high quality synthetic material and only needs little cleaning From time to time we recommend to clean the surface of the unit with a damp cloth In order to preserve the parts we recommend only to use mild cleaning ...

Page 11: ...l section filter replacement M WRG S ventilation unit starts to beep in intervals The M WRG S ventilation unit signals a soon to be done filter replacement Replace the filters see User Manual section filter replacement 6 Antifreeze Protection The M WRG S ventilation unit is equipped with an antifreeze protection In case of very low exterior temperatures the M WRG S ventilation unit will automatica...

Page 12: ...evel Lp in dB A 10 m concealed installation 15 5 24 36 Noise level Lp in dB A 10 m wall mounted 19 24 35 Weight kg approx 8 1 Air duct diameter mm 100 Ventilation unit dimensions Wx H x D in mm 409 x 388 x 196 Filter class filter surface in m Standard filter G4 0 36 Allergy filter optional F 7 0 32 Activated carbon filter optional F 6 0 12 Fully automatic air flap control even during blackouts yes...

Reviews: