background image

Rev 1.2

Mellanox Technologies 

42

Appendix E:  Replacement Parts Ordering Numbers

Table 10 - Replacement Parts Ordering Numbers

Part Description 

OPN

RS232 Cable RJ45 to DB9 Harness

HAR000028

I2C DB9 or RJ45 to USB Adapter

MTUSB-1

Power cord Type C13-C14 

250V 10A 1.5M 

ACC000251

Power cord Type C13-C14 

250V 15A 2M RIGHT ANGLE

ACC000242

Power cord Type B for USA, Canada, Mexico, Taiwan Type B 6ft US 125V 
10A cord

ACC000204

Power cord Type B for USA, Canada, Mexico, Taiwan 

125V15A 4M USA UL (Type B) RIGHT ANGLE

ACC000241

Power cord Type H for Israel

ACC000205

Power cord Type E/F for Sweden, France, Germany, Netherlands, Russia

ACC000207

Power cord Type G for UK

ACC000208

Power cord Type D for India

ACC000209

Power cord Type I for China

ACC000210

Power cord Type J for Switzerland

ACC000211

Power cord Type B for Japan, 

ACC000212

Power cord Type I for Australia

ACC000213

Summary of Contents for SwitchX MSX1016X-2BFR

Page 1: ...www mellanox com SwitchX 64 Port SFP Ethernet Switch Hardware User Manual P N MSX1016X 2BFR MSX1016X 2BRR Rev 1 2...

Page 2: ...ND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS THE CUSTOMER S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET B...

Page 3: ...18 3 3 SFP Cable Power Budget Classification 18 3 4 Interfaces 19 3 4 1 Port Connector Interfaces 19 3 5 Management and Firmware Updating Interfaces 19 3 5 1 RJ 45 Console Connector 19 3 5 2 Mini USB...

Page 4: ...ld Definitions 37 Appendix C Transferring the Power Cord 38 Appendix D SFP Interface 40 Appendix E Replacement Parts Ordering Numbers 43 Appendix F Avertissements de s curit d installation French 44 A...

Page 5: ...Management Interfaces 19 Figure 9 Rack Rail Kit Parts 22 Figure 10 Placement of Switch in Rack 23 Figure 11 Mounting Options 24 Figure 12 Screwing on the Rail 25 Figure 13 Inserting the Caged Nuts 25...

Page 6: ...Status LED Configurations 16 Table 4 Fan LED Configurations 16 Table 5 Bad Port LED Configurations 17 Table 6 Port Connector Physical and Logical Link Indications 18 Table 7 Installation Kit Accordin...

Page 7: ...s 7 Revision History Table 1 Revision History Table Date Revision Description November 2012 Rev 1 2 Removed Updating FW section not needed for Ethernet switches October 2012 Rev 1 1 Added China CCC Wa...

Page 8: ...t this manual the name SX1016 and the term switch are used to describe the 64 port SFP 10Gb s switch unless explicitly indicated otherwise The following icons are used throughout this document to indi...

Page 9: ...otocol 1 2 3 4 Ethernet C Height of Unit 0 1U 1 1 5U 2 2U FF of 40Gb s Ports equivalent 16 G Line rate of the fastest port X 10GbE Separator Power supplies number of power supplies shipped with the ba...

Page 10: ...eb 2 0 High Performance Computing and cloud computing applications Basic installation and hardware maintenance is covered in Hardware Basic Operation and Installation on page 15 Figure 1 SX1016 Switch...

Page 11: ...AC for the switch are found on the back panel The serial number and product version information are found on the label seen in the figure below Near this label is another label with the management MAC...

Page 12: ...a with an ambient temperature exceed ing the maximum recommended 45 C 113 F Moreover to guarantee proper air flow allow at least 8cm 3 inches of clearance around the ventilation openings The chassis s...

Page 13: ...n essential before connecting sup ply Before connecting this device to the power line the protective earth terminal screws of this device must be connected to the protective earth in the building inst...

Page 14: ...is UL Listed and CSA Certified 3 conductor 16 AWG terminated with a molded plug rated at 125 V 13 A with a minimum length of 1 5m six feet but no longer than 4 5m For European connection select a powe...

Page 15: ...connectivity is via the connector side panel All connectors can support active cables 3 1 1 LED Assignments 3 1 1 1 System Status Indicators The System Status Indicators are located on the left side o...

Page 16: ...lug the switch and call your Mella nox representative for assistance If the fan LED shows red unplug the switch and call your Mellanox representative for assistance If the switch shuts down due to ove...

Page 17: ...goes off until the next symbol error is received 3 1 1 5 UID LED Switch Identifier The UID LED is a debug feature that will become available to customers in the near future For details please contact...

Page 18: ...LED when flashing orange shows port physical errors Possible causes for this are bad cable bad connection bad connector bad cage 3 2 Air Flow These switches can come with two air flow patterns The two...

Page 19: ...d the first time the switch is connected A harness is included in the package to connect to a DB9 connection on a host PC Before any remote management is available you must connect to a local host PC...

Page 20: ...I2C Connector There is an I2C interface on the side panel This interface is only for FAEs and advanced users Warning Any red status LED is cause for concern and must be dealt with immediately It can t...

Page 21: ...charge 1 X Harness HAR000028 Harness RS232 2M cable DB9 to RJ45 1 X Quick Start Guide 1 X China RoHS statement 4 1 1 Installing the Switch in the Rack Tools and Customer Supplied Parts 4 1 1 1 Install...

Page 22: ...cted to a verified ground 2 Choose which side of the switch you want even with the rack vertical support Either the side with the power supply units or the side with the SFP connectors can be even wit...

Page 23: ...nd as much as 18 cm on the other side of the rack Keep in mind that there can be as many as 64 data cables plus 1 management cable plus 1 serial cable connected to the switch Do you want the connector...

Page 24: ...r short switches and 7 screws for standard depth switches to connect each switch slide To use the rail kit to transfer the power cord from the connector side to the power side go to Transferring the P...

Page 25: ...nd connector side are at the same level in the rack 6 Clip 4 more caged nuts into the holes on the opposite side of the rack Check that both sides of the switch left and right are the same level in th...

Page 26: ...connecting all of the cables to the switch 4 1 2 Power Connections and Initial Power On Each PSU has a separate AC receptacle The input voltage is auto adjusting for 90 264 VAC 50 60Hz power connecti...

Page 27: ...nto the port with the other end of the connector plugged into a functioning port After plugging in a cable lock the connector using the latching Caution The power supplies in this switch are Double Po...

Page 28: ...cables into the switch always insert the center row cable before the top and bot tom row cables 4 1 5 Cable Orientation The cables need to be inserted according to Figure 15 Figure 15 Cable Orientatio...

Page 29: ...for the First Time See the Installation Guide of the switches Configuring the Switch for the First Time The port labelled must be connected to a local host PC This must be used the first time the swi...

Page 30: ...the Mellanox Support website Copy the update to a known location on a Remote server within the user s LAN Use the CLI or the GUI in order to perform Software upgrade For further information please re...

Page 31: ...cted 2 Check that the locks on the ends are secured 3 Make sure that the latest firmware version is installed on both the cards and the switch 4 If media adapters are used check that the all connectio...

Page 32: ...is not working and unresponsive 1 Unplug the switch 2 Wait 5 minutes 3 Plug in the switch 4 If the switch does not come on check the power supplies 5 If the switch comes on use the management softwar...

Page 33: ...SerDes Speeds 10 Gb s per port Connector Types SFP Air Flow Heat dissipation Air Flow 59 3 CFM Heat dissipa tion Maximum 685 84BTUs hr Power and Environmental Input Voltage Management CPU Input Volta...

Page 34: ...Management Ethernet Auto Negotiation of 10Gb s 1Gb s Management Managed using MLNX OS Data Rate Data Rate 10GigE Regulatory Compliance Safety EMC Emissions Safety US Canada cTUVus EU IEC60950 Interna...

Page 35: ...SwitchX 64 Port SFP Ethernet Switch Hardware User Manual Rev 1 2 Mellanox Technologies 35 A 3 China CCC Warning Statement...

Page 36: ...ill be issued by the MLNX OS management SW indicating to system administration that the switch has crossed the Warning threshold Note that this temperature threshold does not require nor lead to any a...

Page 37: ...1 Once you have decided which side of the switch will be next to the vertical support 2 Make sure that you place the cord so that the correct end of the cord will be at the power side of the switch Th...

Page 38: ...Rev 1 2 Mellanox Technologies 38 Figure 19 Screw the Switch Slide to the Switch Figure 20 Transfer Power Cord Finished 6 Return to step 4 on page 24 and continue the installation...

Page 39: ...rt SFP Ethernet Switch Hardware User Manual Rev 1 2 Mellanox Technologies 39 Appendix D SFP Interface 13 90 11 85 1 80 1 55 44 95 8 50 2 55 0 50 0 60 Mellanox Technologies MTSFPP SR Module 14 80 13 60...

Page 40: ...d 7 RS0 No connection required 8 RX_LOS Loss of Signal indication Logic 0 indicates normal operation e 9 RS1 No connection required 10 VeeR Receiver Ground Common with Transmitter Ground a 11 VeeR Re...

Page 41: ...d if intended for use Pull up voltage should be between 2 0V to Vcc 0 3V A high output indicates a transmitter fault caused by either the TX bias cur rent or the TX output power exceeding the preset a...

Page 42: ...2 Power cord Type B for USA Canada Mexico Taiwan Type B 6ft US 125V 10A cord ACC000204 Power cord Type B for USA Canada Mexico Taiwan 125V15A 4M USA UL Type B RIGHT ANGLE ACC000241 Power cord Type H f...

Page 43: ...13 F Un flux d air de 200LFM cette temp rature ambiante maximale est n cessaire En outre pour garantir un bon coulement de l air laissez au moins 8 cm 3 pouces d espace libre autour des ouver tures de...

Page 44: ...ciales Lorsque ce produit est mont ou entretenu sur baie il faut prendre des pr cautions sp ciales pour s assurer que le syst me reste stable En g n ral il faut remplir la baie avec du mat riel de bas...

Page 45: ...ue du b timent Des enceintes lectriques m caniques et incendie adapt es doivent tre fournies par le fabricant du produit final ou par l utilisateur final Pour les prises lectriques en Am rique du Nord...

Page 46: ...gs ffnungen sein um einen einwandfreien Luftstrom zu gew hrleisten Das Chassis sollte nicht auf andere Ger te gestapelt werden Wenn das Chassis herun terf llt kann es zu Verletzungen und Besch digunge...

Page 47: ...Sie das Gestell von unten nach oben mit Ger ten f llen Diese Ger t sollte nur von geschultem und qualifiziertem Personal installiert ausge tauscht oder gewartet werden Die Entsorgung dieses Ger ts sol...

Page 48: ...indung von wesentlicher Bedeutung werden Bevor Sie dieses Ger t an das Stromnetz die Schutzerde Terminal Schrauben dieses Ger t muss an den Schutzleiter in der Geb udeinstallation Dieses Ger t muss in...

Page 49: ...ual Rev 1 2 Mellanox Technologies 49 20 Bodily Injury Due to Weight Use enough people to safely lift this product 40 lbs 18 kgs 40 70 lbs 18 32 kgs 70 121 lbs 32 55 kgs 121 lbs 55 kgs 40 lbs 18 kgs 40...

Page 50: ...ical lift to avoid injuries No se debe utilizar el equipo en un rea con una temperatura ambiente superior a la m xima recomendada 45 C Adem s para garantizar una circulaci n de aire adec uada se debe...

Page 51: ...r adver tencias o instrucciones especiales consultar al fabricante del cable Al instalar o realizar el mantenimiento de este aparato en un bastidor es preciso adop tar precauciones especiales para gar...

Page 52: ...n con la puesta a tierra de protecci n y un t cnico de servicio deber conectar permanentemente el equipo a dicho medio de conexi n Un T CNICO DE SERVICIO comprobar si la toma el ctrica de la que se s...

Page 53: ...national electrical codes in Denmark The AC cord shall have an integral ground wire and can only be plugged into a fully grounded outlet Finland Norway Sweden Do not connect this unit to any outlet t...