Dismantling Guide

 

Rev. 1.0 

 

 

 

 

 

Mellanox Technologies Confidential

 

 

 

2 of 12

 

 

 

NOTE: 

THIS INFORMATION IS PROVIDED BY MELLANOX FOR INFORMATIONAL PURPOSES ONLY 
AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE 
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE 
ARE DISCLAIMED. IN NO EVENT SHALL MELLANOX BE LIABLE FOR ANY DIRECT, 
INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES 
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; 
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND 
ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT 
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF 
THIS HARDWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. 

 

 

 

Mellanox Technologies, Inc. 

350 Oakmead Parkway Suite 100 

Sunnyvale, CA 94085 

 

U.S.A. 

www.mellanox.com

  

Tel: (408) 970-3400 

Fax: (408) 970-3403 

Mellanox Technologies Ltd 

PO Box 586 Hermon Building 

Yokneam 20692 

Israel 

Tel: +972-4-909-7200 

Fax: +972-4-959-3245 

 

 

 © Copyright 2011. Mellanox Technologies, Inc. All Rights Reserved. 

Mellanox®, BridgeX®, ConnectX®, InfiniBlast®, InfiniBridge®, InfiniHost®, InfiniRISC®, 
InfiniScale®, InfiniPCI®, PhyX® and Virtual Protocol Interconnect® are registered trademarks of 
Mellanox Technologies, Ltd. CORE-Direct and FabricIT are trademarks of Mellanox Technologies, Ltd.  

All other marks and names mentioned herein may be trademarks of their respective companies.

Contact Information

 

 
Should you have any questions regarding our Products, please feel free to contact us directly or contact our 
local distributors. 
 

Mellanox Technologies Call Center  

Tel: + 
Email: 

[email protected]

 

Summary of Contents for MIS5023

Page 1: ...Document no 3396 Mellanox Technologies Confidential http www mellanox com Dismantling Guide OPNs MIS5024 MIS5023 Rev 1 0 ...

Page 2: ...RE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Mellanox Technologies Inc 350 Oakmead Parkway Suite 100 Sunnyvale CA 94085 U S A www mellanox com Tel 408 970 3400 Fax 408 970 3403 Mellanox Technologies Ltd PO Box 586 Hermon Building Yokneam 20692 Israel Tel 972 4 909 7200 Fax 972 4 959 3245 Copyright 2011 Mellanox Technologies Inc All Rights Reserved Mellanox BridgeX ConnectX InfiniBlast Infi...

Page 3: ... 6 1 3 Cover 6 1 4 Extracting the Power Supply Unit 7 1 5 Extracting the Fan Unit 9 1 6 Extracting the Board 11 List of Tables Table 1 Revision 4 Table 2 Switch OPNs for this Procedure 4 List of Figures Figure 1 Remove the Cover 7 Figure 2 PSU Location 8 Figure 3 PSU Screw Locations 8 Figure 4 Fan Location 9 Figure 5 Fan Bottom Side Screw Locations 10 Figure 6 Fan Top Side Screw Locations 10 Figur...

Page 4: ...nts of WEEE recycling Intended Audience This manual is intended for technicians who dismantle the switch systems as a reference for WEEE recyclers Mellanox Technologies emphasizes the importance of carefully following all procedures described in this guide to prevent personal injury Switch OPNs This document is valid for all of the switch OPNs listed in Table 2 Table 2 Switch OPNs for this Procedu...

Page 5: ...g the requirements of the European Union s WEEE waste electrical and electronic equipment directive The directive mandates how the materials used in electrical and electronic equipment must be disposed of Mellanox Technologies has worked closely with its suppliers to eliminate hazardous materials from its products There are instances however where it has not proven possible to completely eliminate...

Page 6: ... the product part number represents the RoHS type For example MIS5024Q 1BRR the last R RoHS 6 InfiniBand switch system systems are comprised of Main Board Fan unit Harnesses Power Supply Unit PSU Cover 1 2 General Preparations The InfiniBand switch system is assembled using Philips screws To disassemble the InfiniBand switch system you will need a small Philips screwdriver The pictures displayed i...

Page 7: ...chnologies Confidential 7 of 12 Figure 1 Remove the Cover 1 4 Extracting the Power Supply Unit The power supply unit is located on the rear side of the switch unit Disassemble the 4 screws attaching the Power Supply to its mechanical base ...

Page 8: ...Dismantling Guide Rev 1 0 Mellanox Technologies Confidential 8 of 12 Figure 2 PSU Location Figure 3 PSU Screw Locations Power Supply Schema Screws for disassembling the PS from the base ...

Page 9: ...the power supply cord from the power supply unit 3 Unscrew the power supply from the mechanical enclosure 1 5 Extracting the Fan Unit The Fan unit is located in the middle of the system Figure 4 Fan Location 1 Disconnect the harnesses from the fan unit to the board 2 Disassemble the 3 screws attaching the Fan wall to the bottom of the mechanical enclosure base ...

Page 10: ... 10 of 12 Figure 5 Fan Bottom Side Screw Locations 3 Disassemble the 2 screws attaching the Fan wall to the sides of the mechanical base 4 Remove the fan unit 5 Disconnect harness tie downs and remove harnesses from the base Figure 6 Fan Top Side Screw Locations ...

Page 11: ...0 Mellanox Technologies Confidential 11 of 12 1 6 Extracting the Board 1 Unscrew the heat sink screws to remove the heat sink 2 Unscrew the Philips screws and remove spacers to remove the main board Figure 7 Main Board Removal ...

Page 12: ...Dismantling Guide Rev 1 0 Mellanox Technologies Confidential 12 of 12 Figure 8 Main Board Screws ...