Enable NETWORKING support [Y/n]: (Default “Yes”)
Enable NETWORKING_IPV6 support [y/N]: (Default “No”)
Enter GATEWAY an IP Address: <IP_ADDRESS>
Enter a hostname [Ex: localhost.localdomain]:<IS4.example.com>

The new HOST configuration will be displayed and you will be asked if you want to save it.

Selected configuration:
NETWORKING=yes
NETWORKING_IPV6=no
GATEWAY=<IP_ADDRESS>
HOSTNAME=<hostname.domainname>
Do you want to save the selected configuration? [Y/n]: (Default “Yes”)

Y – will save the new configuration and ask you if you want to change the IP address configuration

 

N – will redirect you to the main menu

If you answer ‘N’ to the first question above under “

Configure Host Networking

” about changing the 

host configuration, it will implement the current configuration and ask you if you want to change the IP 
address configuration.

Do you want to configure IP Address? [Y/n]: (Default “Yes”)

N - will redirect you to the main menu

 

Y – will open the configure IP address flow

Configure IP Address

Selection 2 under the config_net brings you to this flow. It will show the current configuration and ask if you 
want to change it.

Configure IP Address
1) Configure by DHCP
2) Static Configuration
3) Exit
Enter Your Selection:

Selection # 1) Configure by DHCP – will show the current configuration and ask you if you want to change 
it.

The current IP configuration for eth0 is:
DEVICE=eth0
BOOTPROTO=static
IPADDR=<IP_ADDRESS>
NETMASK=<NET_MASK>
HWADDR=<MAC_ADDRESS>
ONBOOT=yes
Do you want to change this configuration? [y/N]: (Default “No”)

N - will redirect you to the main menu

 

Y – will show the configuration for DHCP and ask you if you want to save it

The used configuration is:
DEVICE=eth0
ONBOOT=yes
HWADDR=<MAC_ADDRESS>

Summary of Contents for BX4000 Series

Page 1: ...orresponding downlink ports Each gateway port group is assigned a color to easily associate the uplink ports to the corresponding downlink ports of the gateway port group Figure 1 MTB 4010 Gateway Por...

Page 2: ...k ports per gateway port group These ports have SFP connectors that support both direct attach copper cable and optical cables by using a SR or LR modules The downlink ports are labelled alpha numeric...

Page 3: ...carrying on with installation procedures Installation Safety Warnings For Safety Warnings in French and German and for special regulations regarding Finland Sweden Den mark and Norway see the gateway...

Page 4: ...system remains stable In general you should fill the rack with equipment starting from the bottom to the top This equipment should be installed replaced or serviced only by trained and qualified perso...

Page 5: ...de All connectivity is via the connector side panel All connectors can support active cables Figure 3 MTB4010B Gateway System Power Side and Connector Side Panels Package Contents The package should i...

Page 6: ...en sent check this against the parts list Check the parts for visible damages that may have occurred during shipping Note If anything is damaged or missing contact your customer representative immedia...

Page 7: ...ck and the door can be as little as 4 cm on one side of the rack and as much as 18 cm on the other side of the rack Keep in mind that there can be as many as 10 cables for the MTB4010B onnected to the...

Page 8: ...he rails Figure 6 Clipping in the Caged Nuts 4 Using two of the pan head screws and one washer for each rail install the rails to the end of the rack Place the rail behind the holes in the rack and sc...

Page 9: ...irmly seated The GREEN LED indicator above of each CX4 ports or above or below each SFP port will light when the physical connection is established that is when the unit is powered on and a cable is p...

Page 10: ...ions Access through Serial Port 1 Connect the host PC to the RS 232 port of the MTB4000 series gateway using the supplied cable 2 Make sure to connect to the RS 232 RJ 45 port of the switch and not to...

Page 11: ...PU Ethernet port to your local 1Gigabit Ethernet network 2 Connect any Linux station to the Ethernet 3 At the prompt enter ssh admin 172 22 2 2 4 Enter the password Password admin Access through Telne...

Page 12: ...when you run a sudo command The sudo command will ask for your password each time you run it If you logout from the current session or if it closes by timing out 10 min you will be asked for your pas...

Page 13: ...n it will implement the current configuration and ask you if you want to change the IP address configuration Do you want to configure IP Address Y n Default Yes N will redirect you to the main menu Y...

Page 14: ...es After completing these selections the selected configuration will be displayed and you will be asked if you want to save it Selected configuration DEVICE eth0 BOOTPROTO static IPADDR IP_ADDRESS NET...

Page 15: ...or full use of FabricIT The standard management module without a license allows for managing the gateway using the Web interface or the com mand line interface and software supplied on the management...

Reviews: