Melexis EVB90640 User Manual Download Page 7

EVB90640/1 

User manual 
 

Rev. 2 

 

Page 7 of 7

    

 

 

4.

 

Disclaimer 

The information furnished by Melexis herein (“Information”) is believed to be correct and accurate. Melexis disclaims (i) any and all liability in connection with or arising out of the 
furnishing,  performance  or  use  of  the  technical  data  or  use  of  the  product(s)  as  described  herein  (“Product”)  (ii)  any  and  all  liability,  including  without  limitation,  special, 
consequential  or  incidental  damages,  and  (iii)  any  and  all  warranties,  express,  statutory,  implied,  or  by  description,  including  warranties  of  fitness  for  particular  purpose,  non-
infringement and merchantability. No obligation or liability shall arise or flow out of Melexis’ rendering of technical or other services. 
The  Information  is  provided  "as  is”  and  Melexis  reserves  the  right  to  change  the  Information  at  any  time  and  without  notice.  Therefore,  before  placing  orders  and/or  prior  to 
designing the Product into a system, users or any third party should obtain the latest version of the relevant information to verify that the information being relied upon is current.   
Users  or  any  third  party  must  further  determine  the  suitability  of  the  Product  for  its  application,  including  the  level  of  reliability  required  and  determine  whether  it  is  fit  for  a 
particular purpose. 
The Information is proprietary and/or confidential information of Melexis and the use thereof or anything described by the Information does not grant, explicitly or implicitly, to 
any party any patent rights, licenses, or any other intellectual property rights.  
This document as well as the Product(s) may be subject to export control regulations. Please be aware that export might require a prior authorization from competent authorities.  
The Product(s) are intended for use in normal commercial applications. Unless otherwise agreed upon in writing, the Product(s) are not designed, authorized or warranted to be 
suitable  in  applications  requiring  extended  temperature  range  and/or  unusual  environmental  requirements.  High  reliability  applications,  such  as medical  life-support  or  life-
sustaining equipment are specifically not recommended by Melexis.  
The Product(s) may not be used for  the following applications subject to export  control regulations: the development, production, processing, operation,  maintenance, storage, 
recognition  or  proliferation  of  1)  chemical,  biological  or  nuclear  weapons,  or  for  the  development,  production,  maintenance  or  storage  of  missiles  for  such  weapons:  2)  civil 
firearms, including spare parts or ammunition for such arms; 3) defense related products, or other material for military use or for law enforcement; 4) any applications that, alone 
or in combination with other goods, substances or organisms could cause serious harm to persons or goods and that can be used as a means of violence in an armed conflict or any 
similar violent situation.  
The  Products  sold  by  Melexis  are  subject  to  the  terms  and  conditions  as  specified  in  the  Terms  of  Sale,  which  can  be  found  at https://www.melexis.com/en/legal/terms-and-
conditions.  
 
This document supersedes and replaces all prior information regarding the Product(s) and/or previous versions of this document. 
 
Melexis NV © - No part of this document may be reproduced without the prior written consent of Melexis.  (2016) 

 

ISO/TS 16949 and ISO14001 Certified 

Summary of Contents for EVB90640

Page 1: ...ct EVB90640 Evaluation Board MLX90640 Insert the sensor in the ZIF socket on the PCB Take care to align the notch with the silk screen on the PCB Next connect the PCB with the USB port of the computer...

Page 2: ...inear interpolation of the thermal image x1 x2 or x4 The sub frame rate of the sensor 0 5Hz 1Hz 2Hz 4Hz 64Hz Initially the software reads the frame rate as set in the EEPROM of the sensor The factory...

Page 3: ...is shown in a new screen In the top right corner one can see the maximum and minimum temperature of the temperature scale the sensor temperature Ta and the temperature To of the pixel at the pointer...

Page 4: ...e actual measurement range One can also choose the desired temperature unit and mirror the image if needed for presentation purposes The restart on full EVB assures that the EVB would restart by itsel...

Page 5: ...of one full frame 768 pixels in one line The next frame is stored on the next line Each line starts with a timestamp followed by the temperature reading of each individual pixel row by row After 768...

Page 6: ...er the EEPROM tab there is also a tab to export the EEPROM information to file and a button to upload new firmware to the EVB if needed Here is also a tab to point the program to the file directory wh...

Page 7: ...ent as well as the Product s may be subject to export control regulations Please be aware that export might require a prior authorization from competent authorities The Product s are intended for use...

Reviews: