DB-2620Av1
Instructions Manual
10.Specifications
10-1.General Specifications
DC+24V
*1 (Ripple voltage P-P 2.0V or less)
● Rated input current :
〔DRIVE I.SEL ⇒ No.F set up〕
at DRIVE
DC+24V: 2.5A
*2
● Rated input current :
〔HOLD I.SEL ⇒ Approx. 40% set up〕
at HOLD
DC+24V: 0.6A
●DRIVE CURRENT
0.30A/phase~2.00A/phase
●HOLD CURRENT
Approx. 40% of DRIVE CURRENT
(factory-set)
●Drive pulse input
(CW,CCW)
Photo-coupler input
●Motor excitation stop input
(M.F)
Photo-coupler input
●STEP ANGLE selection
(STEP SEL)
●HOLD CURRENT selection
(HOLD I.SEL)
●DRIVE CURRENT selection
(DRIVE I.SEL)
●PULSE INPUT TYPE selection
(SPI SEL)
●ROTATE CHARACTERISTIC selection
(R.C SEL)
Indoor (Exposure to direct sun is not allowed.)
*1
Input voltage range is DC+24V±10%.
*2
Use a power supply that provides sufficient input current.
Functions of
Operating Sections
Operating Ambient
Temperature
0℃ ~ +40℃
(No freezing allowed.)
Supply Power
Driving method
Unipolar constant current type
Motor output
current
Input Signal
Operating Ambient
Humidity
80%RH 以下
(No condensation allowed.)
Storing Temperature -10℃ ~ +55℃
(No freezing allowed.)
Storing Humidity
80%RH or less
(No condensation allowed.)
Altitude
Up to 1000m above sea level
Exterior Dimensions
H
77 ×
W
88 ×
D
30 (mm)
Weight
0.11kg
Atmosphere
Without any explosive, corrosive or inflammable gas, oil mist,
or dust.
Withstanding
Vibration
No abnormality should be found after a vibration test
at 10~55Hz, 0.15mm P-P
Insulation
resistance
DC connector - signal connector - Frame
(Each other)
DC500V 100MΩ or more
-26-