- 3 -
Description of Safety
This product must be handled correctly.
Handling the product incorrectly may cause unexpected accidents resulting in personal injuries or
damage to your properties.
Many of those accidents can be avoided if you have advance information on dangerous situations.
This manual provides precautions where dangerous situations are predicted.
The manual provides the
following alert marking and messages for this purpose:
This indicates a hazardous situation that could result in death or serious
WARNING
personal injury if you do not perform the procedure correctly.
This indicates a potentially hazardous situation that could result in personal
CAUTION
injury or physical damage if you do not perform the procedure correctly.
Before Use
■Set up the product before operating it.
Refer to Section 3, "Setting."
■This product is equipped with a LIMIT (overtravel) signal and an FSSTOP signal to prevent mechanical
damage.
The initial values of these signals are set to ACTIVE OFF (B contact).
Accordingly, even in a
system configuration in which the FSSTOP and LIMIT signals are not used, pulses are not output
unless NORMAL ON (GND connection) is enabled.
■The C‑VX875 allows axes to be controlled independently and therefore referred to each axis
as follows:
1st axis
2nd axis
3rd axis
4th axis
X axis
Y axis
Z axis
A axis
・AL‑Ⅱ I/O communication of C‑VX875 explains C‑VX875 as a master board.
・This manual basically explains only the X axis.
■Please also read the device driver operation manual for Windows which suited this product.
C-VX875
Instructions Manual