- 15 -
C-VX875
Instructions Manual
2‑6.
Input and Output Signal Table
(1) User I/O connector (J1)
■Pin assignments
(J1)
・Connector type name
:HDRA‑E100LFDT‑SL+ (HONDA TSUSHIN KOGYO)
・Adaptable socket
:HDRA‑ ,HDRA‑ etc.
(HONDA TSUSHIN KOGYO, not included in attached accessories)
(Adaptable socket is 100‑pin)
・Adaptable cable
:CE‑33‑E4/100A10 (1 m in length)
CE‑34‑E4/100A20 (2 m in length)
CE‑35/E4‑100A30 (3 m in length)
CE‑36/E4‑100A50 (5 m in length)
* The above‑mentioned conformity cables are not accessories.
Although C‑VX875 is a 4 axis controller, the suiting cable becomes
"8 axes and 12 axis controllers."
Reference
For more information about a cable preparing in the
C‑VX870 series, refer to the instruction manual of
"The connecting cable for board controllers" .
■Signal table
This product may be damaged.
CAUTION
Do not c24V to any pin other than EXTV.
After wiring, be sure to confirm the wiring before power‑on.
● A signal indicated by
is photocoupler‑insulated.
● A signal is enable to set time constants marked with ☆.(Applied function)
● Logic switching is enabled for an input signal marked with ★.(Applied function)
Logic switching is enabled for general‑purpose input signal INx,
when this signal is used for DALM function
(Note 1)
An external power supply is required for a signal that is photocoupler‑insulated.
The specified input voltage range is +24V ±2V.
Current consumption at +24V is up to 200mA.
The initial values of the CWLM and CCWLM signals of each axis and the FSSTOP signal are
ACTIVE OFF input (B contact).
An external power supply must be connected even if these signals are not used.
The default contact B is recommended for the CWLM and CCWLM signals.
However, A‑contact signal input can also be used by switching logic.
(Note 2)
SENSORx input signals are used for multipurpose sensor function, synchronization control
function. These input signals is used by any functions setting.(Applied function)
The initial value after resetting is as follows:
SENSOR0 signal is SS0 of Z‑axis, SENSOR1 signal is SS0 of A‑axis.
When SENSORx input signal is used for multipurpose sensor function, this signal can not use
in MANUAL mode.
When MANUAL mode, the functions of multipurpose sensor assigned to the SENSORx input
signal
are invalid.
When BUS mode, this function are valid.