MEITRACK Driver Fatigue Monitor System User Guide
Copyright © 2019 Meitrack Group All rights reserved. - 14 -
Command Description
1.
Parameter
A
: indicates the alert volume. The parameter value is
0
,
1
,
2
, and
225
. Decimal.
0
: No sound.
1
: Medium volume.
2
: High volume.
225
: reserved for DIP switches.
Parameter
B
,
C
,
D
, and
E
: indicates an alert. Decimal.
B
: Absence alert.
0
: function disabled.
1
: function enabled.
C
: Distraction alert.
0
: function disabled.
1
: function enabled.
D
: Smoking alert.
0
: function disabled.
1
: function enabled.
E
: On Phone Call alert.
0
: function disabled.
1
: function enabled.
2.
If you want to read the parameters, send
C90
.
3.
Parameter settings must be complete.
4.
If the network connection is poor or parameter settings are not correct, an error code will be replied.
Example
@@R35,868725036977468,C90,2,1,1,1,1*60
$$R28,868725036977468,C90,OK*1E
Setting the Sensitivity(Telephone) (SMS/GPRS) – BA6
Sending BA6,X
Reply
BA6,OK/<
Error code
>
Command Description
1.
Parameter
X
: indicates the telephone detecting sensitivity. Default 4. Value range from 3~300. Decimal.
2.
If you want to read the parameters, send
BA6
.
3.
If the network connection is poor or parameter settings are not correct, an error code will be replied.
Example
@@R27,868725036977468,BA6,4*FC
$$R28,868725036977468,BA6,OK*2B
9
GPRS Protocol About Alert Event 114
Driver fatigue alert
(event code 114).
For details, see the
assisted event info of
Meitrack GPRS
Protocol.
Driver fatigue alert
Format: A|B|C
A
: indicates the Montor version. The
parameter value is
01
. Decimal.
B
: indicates the alert type. Contains 2
characters; decimal.
01
: Mild fatigue
02
: Moderate fatigue
03
: Severe fatigue
04
: Distraction alert
05
: Absence alert
06
: On Phone Call alert
07
: Smoking alert
08
: Yawning alert
C
: indicates the additional alert information.
$$b185,868725036977468,AAA,
114,22.513633,114.057243,180
704002342,A,11,24,40,288,0.9,2
9,1,50063,460|1|252F|00003BF
9,0000,0001|0000|0000|019B|
04CA,
01|08|180704002340_Ya
wning.jpg
,,3,,,30,41*E7
It indicates version 01, a
yawning alert, photo name