The functions of DIP switches are as follows:
DIP Switch
Function
DIP1
Switch on: low sensitivity. When drivers close the eyes or are distracted,
it will take about 5 seconds to generate an alert.
Switch off: high sensitivity. When drivers close the eyes or are
distracted, it will take about 1 or 2 seconds to generate an alert.
DIP2
Switch on: When the speed is larger than 15 km/h, an alert will be
generated.
Switch off: When the speed is larger than 30km/h, an alert will be
generated.
DIP3
Switch on: The yawning alert function will be enabled.
Switch off: The yawning alert function will be disabled.
DIP4
Switch on: The debug mode will be enabled. An alert will be generated,
no matter what the speed is. This will help users test the alert function
indoors or in an underground parking lot.
Switch off: The debug mode will be disabled, and the DIP2 switch will
work.
7
Meitrack Manager Configuration
7.1
Setting the GPRS Event
On the
Event
tab page, locate
Driving Behavior
, and select
GPRS
. When the Monitor detects an alert, a GPRS event
will be sent to the MS03 tracking platform.