7.2 Install I/O Cable
7.2.1 The Definition of I/O Cable
The I/O cable includes power, analog input, negative/positive input and output.
I/O
Color
Description
Digital Input 1 (SOS)
Input: White
Ground Wire: Black
Alarm while input1 triggering (Or press SOS).
Digital Input 2
White
Input2 is available for high level and low level, default is low level
for detecting door.
Digital Input 3(Door)
Grey
Input3 is available for high level and low level, default is low level
for detecting door.
Digital Input 4(ACC)
Brown
High level input (3~60V), default for ACC detection.
Digital Input 5(RPM)
Green
Detect the signal cable of vehicle speed sensor for detecting
speed.
Digital Output
Yellow
Open-Drain Output, the power circuit of output is 1W, 0~100V.
Ground Wire
Black
GND
Power
Positive of Power: Red
Ground Wire: Black
Main Power of the device, DC 11~36V, hardware under-voltage,
overvoltage protection
Buzzer Output
Output: Brown
Output: White
PWM Output: connect with buzzer
Positive Power Cord: Brown; Ground Wire: White
Fuel Capacity AD
Detection Port
Positive of Power: Red
Ground Wire: Black
AD Cable: Blue
0~5V AD detection
Output positive power is the input voltage of the device (Only for
Meitrack Protocol)
The interface should match the fuel sensor
Temperature
Detection Port
Positive of Power: Red
Ground Wire: Black
USB Cable: Green
The positive of the power is the output voltage of the device 5V.
The interface should match the temperature sensor. (Only for
Meitrack Protocol)
Microphone and
Speaker
Green and Red
Green is speaker
Red is microphone
Remote Control
Antenna
Black
Copyright © 2014 Meitrack Group All rights reserved.