background image

MEITRACK Ultrasonic Fuel Level Sensor User Guide                                                                                       

 

Copyright © 2022 Meitrack Group All rights reserved.                                                          - 5 -

 

3

 

Accessories 

Standard accessories: 

Standard Accessories 

Quantity 

Picture 

Probe (integrated type) 

1 pcs 

 

Diameter: 

φ33

 mm 

Height: 12 mm 

Wire length: 1m (including the connector) 

Protective holder and ring gasket 

1 pcs 

 

Fuse 

1 pcs 

 

8m extension cable 

1 pcs 

 

Wire length: 8m (including the connector) 

8 pin to 4 pin conversion cable 

1 pcs 

 

rubber pad and 2.5m length steel 

clamp (Quantity is selected according 

to installation requirements) 

 

 

 

Sandpaper 

1 pcs 

Used to clean the bottom of the fuel tank. 

Note: There are two ways to fix the sensor probe, 1. ring  steel clamp, 2. strong magnetic  AB glue. the 

standard for A76-100 and A76-250 is the first one, ASUF105 is the second one. If you choose A76 for fuel tanker, it is 
recommended to use the second one, please consult the sales for such case. 

Optional accessories: 

Optional Accessories 

Picture 

AB  glue  (unable to go through logistics, so  cannot 

provide. Only for reference) 

 

Couplant (unable to go through logistics, so cannot 

provide. Only for reference) 

 

Summary of Contents for A76-100

Page 1: ...MEITRACK Ultrasonic Fuel Level Sensor User Guide A76 100 A76 250 ASUF105 Ultrasonic Fuel Level Sensor User Guide...

Page 2: ...Meitrack Group All rights reserved 2 Change History File Name MEITRACK Ultrasonic Fuel Level Sensor User Guide Project Creation Date Update Date 2016 03 31 2022 09 14 Subproject Accessory User Guide...

Page 3: ...nctions and Specifications 4 2 1 Product Functions 4 2 2 Specifications 4 3 Accessories 5 4 Installation 6 4 1 WiFi tool Optional Accessory 6 4 2 Installing the Sensor 6 4 3 Installing the Tracker 13...

Page 4: ...duct or documentation 2 Product Functions and Specifications 2 1 Product Functions Measure vehicle s fuel level Detect an alarm when the fuel level is too high Detect an alarm when the fuel level is t...

Page 5: ...length steel clamp Quantity is selected according to installation requirements Sandpaper 1 pcs Used to clean the bottom of the fuel tank Note There are two ways to fix the sensor probe 1 ring gasket...

Page 6: ...u can t get it use toothpaste instead 3 AB glue is available on websites such as amazon The model is 3M DP110 As the following picture 4 Installation 4 1 WiFi tool Optional Accessory This WiFI tool is...

Page 7: ...check the fuel level You can use any of the preceding ways to determine whether the fuel tank is half full and estimate the fuel level 3 Know more information about probe installation When sticking t...

Page 8: ...nd keep the area dry 4 Configure the WiFi tool 1 Connect the sensor with WiFI tool first 2 Connect the WiFi tool to power bank and power on Once conncted the red indicator light is on 3 Turn on the li...

Page 9: ...up the couplant on the fuel tank and probe and keep the probe installation location dry If the bottom of the fuel tank is covered with paint use the putty knife or screwdriver to scrape paint Then us...

Page 10: ...ition please clear the testing couplant on the surface of fuel tank and sensor completely 1 Install the A76 100 or A76 250 Install the protective holder Please make sure the center of the holder match...

Page 11: ...install the steel clamp Stick the rubber pad on the four corners of tank Fasten the steel clamp Fasten the joint of the clamp with a cable tie Check the installation status on the APP 2 Install the AS...

Page 12: ...within 2 3 mm and find the right installation location If the ambient temperature is 25 C move the probe for 30 seconds after sticking the probe In this way if the result is unable to install remove t...

Page 13: ...he Tracker 1 Using RS232 standard interface The device wiring diagram is as follows Note 1 Both RS232 ports of T633L support the connection of ultrasonic fuel sensor RS232 1 can be connected directly...

Page 14: ...pported 2 Connecting with AD input connection as below Devoce I O cables Extention cables Red external power supply Red 9 36VDC Black GND Black AD input cable Green AD 0 5V Note 1 The color of the AD...

Page 15: ...e following figure Click Set to save the configuration Note 1 When connecting with RS232 port the full oil value must be set according to the actual tank height otherwise the oil percentage will not b...

Page 16: ...n also set the sensor by MS03 tracking system Please ensure that the tracker is online On MS03 choose Management On the Management window select Parameter settings from Use Normal On the page that is...

Page 17: ...MS03 choose Reports 2 On the Reports window select Historical data from Use Normal The Historical data window is displayed 3 Select a tracker set the query time and click The results will be displayed...

Page 18: ...Copyright 2022 Meitrack Group All rights reserved 18 2 Select a tracker and sensor set the query time and click The results will be displayed as shown in the following figure If you have any questions...

Reviews: