4. Technician Settings
Enter technician settings
- 18 -
(Press and hold)
Adjust the set-point temperature to 10ºC.
To enter technician settings, press and hold the button for
5 seconds.
Use the button to advance to the next parameter.
Use the button to return to return to the previous parameter.
Press the button or wait 60 seconds to exit technician settings
and return to normal display.