
4 GNSS Receiver
4.1.3.13 Menu: Output Options
>Output Options<
Serial Outputs
IRIG Output
Pulse Outputs
>enable Outputs<
Time Zone
ENABLE OUTPUTS
Serial: always
Pulses: if sync
Set Timezone
->DL Sav ON <-
DL Sav OFF
OK
OK
enable Outputs
Time Zone
>
<
OK
Enable Outputs:
The submenu
Output Options -> Enable Outputs
lets the user configure at which time after power up the serial
ports and pulse/frequency outputs are to be enabled. Outputs which are shown to be enabled ’always’ will be
enabled immediately after power-up. Outputs which are shown to be enabled ’if Sync’ will be enabled after the
receiver has decoded the incoming signals and has checked or corrected its on-board clock. The default setting
for all outputs is ’if Sync’.
Time Zone:
See Chapter "Set Time Zone of Serial Outputs".
IMS-GNS181 Setup Guide
Date: 20th March 2020
39