![Meinberg GPS165 Manual Download Page 54](http://html1.mh-extra.com/html/meinberg/gps165/gps165_manual_1766202054.webp)
8.4.10 Format of the RACAL standard Time String
The RACAL standard Time String is a sequence of 16 ASCII characters terminated by a X (58h) character and
ending with the CR (Carriage Return, ASCII Code 0Dh) character. The format is:
<X><G><U>
yymmddhhmmss
<CR>
The letters printed in italics are replaced by ASCII numbers whereas the other
characters are part of the time string. The groups of characters as defined below:
<X>
Control character
code 58h
sending with one bit
accuracy at change of second
<G>
Control character
code 47h
<U>
Control character
code 55h
yymmdd
the current date:
yy
year of the century
(00..99)
mm
month
(01..12)
dd
day of month
(01..31)
hh:mm:ss
the current time:
hh
hours
(00..23)
mm
minutes
(00..59)
ss
seconds
(00..59, or 60 while leap second)
<CR>
Carriage Return, ASCII code 0Dh
Interface
parameters:
7 Databits, 1 Stopbit, odd. Parity, 9600 Bd